Description of device parameters
Waterpilot FMX21
96
Hauser
14.7 Expert → Measurement → Level
Level selection
Write permission
Operator/Maintenance/Expert
Description
Select the method for calculating the level
Options
• In pressure
If this option is selected, specify two pressure/level value pairs. The level value is
displayed directly in the unit that you select via the "Output unit" parameter.
• In height
If this option is selected, specify two height/level value pairs. From the measured
pressure, the device first calculates the height using the density. This information is then
used to calculate the level in the "Output unit" selected using the two value pairs
specified.
Factory setting
In pressure
Output unit
Description
Select the unit for the measured value display for the level before linearization.
Note
The selected unit is used only to describe the measured value i.e. when a new output unit
is selected, the measured value is not converted.
Example
• Current measured value: 0.3 ft
• New output unit: m
• New measured value: 0.3 m
Options
• %
• mm, cm, dm, m
• ft, inch
• m
3
, in
3
• l, hl
• ft
3
• gal, Igal
• kg, t
• lb
Factory setting
%
Height unit
Write permission
Operator/Maintenance/Expert