BA176C/07/en/08.07
71060783

Operating Instructions

Turbimax W CUS31

Turbidity sensor

Содержание Turbimax W CUS31

Страница 1: ...BA176C 07 en 08 07 71060783 Operating Instructions Turbimax W CUS31 Turbidity sensor...

Страница 2: ...Endress Hauser...

Страница 3: ...he transmitter 13 4 2 Post connection check 13 5 Commissioning 14 5 1 Function check 14 5 2 Calibration 14 5 3 Setting the wiper 14 6 Maintenance 15 6 1 Cleaning the sensor 15 6 2 Checking the measuri...

Страница 4: ...technical personnel must be authorized for the specified activities by the system operator Electrical connection must only be carried out by a certified electrician Technical personnel must have read...

Страница 5: ...cond last page of these Operating Instructions with the packaging and the transportation documents No repair without completed declaration 1 5 Notes on safety icons and symbols Warning This symbol ale...

Страница 6: ...h fixing bracket CUS31 S installed and factory calibrated in assembly with gas bubble trap with fixing bracket Operating Instructions BA176C 07 en If you have any questions please contact your supplie...

Страница 7: ...e of delivery is complete and agrees with your order and the shipping documents The packaging material used to store or to transport the product must provide shock protection and humidity protection T...

Страница 8: ...alls should be and the greater the wall distance should also be When measuring in drinking water the wall distance to a dark wall must be at least 8 cm 3 Bright pipes are not suitable for the drinking...

Страница 9: ...al pipe it 5 Do not install the sensor in places where air may collect or foam bubbles form it 3 or where suspended particles may settle it 2 Avoid installation in the down pipe it 4 3 2 4 Flow operat...

Страница 10: ...slight overpressure forms in the assembly as a result of the height difference of the raised outlet 4 Incorrect Outlet raised but not vented A low pressure forms in the assembly if venting via the do...

Страница 11: ...tion For this reason select an installation location in which a minimum wall distance of 150 mm 6 is observed even with varying levels or altered flow profiles Mounting in a suspended assembly with ch...

Страница 12: ...sed at least 4 cm 1 5 into the medium Please pay special attention to the installation instructions in the Operating Instructions of the assembly used 3 4 Post installation check a0008114 Fig 11 Measu...

Страница 13: ...ions on sensor connection in the Operating Instructions of the transmitter 4 2 Post connection check GN YE WH BN GND Com A Com B UB UB CUS31 CUM2x3 S 96 97 88 87 Instrument status and specifications R...

Страница 14: ...ngeable without losing the factory calibration in data record 1 Note Please pay special attention to the instructions on wall distance An installation adjustment see Operating Instructions BA200C 07 e...

Страница 15: ...leaning depend on the medium The sensor must be cleaned prior to every calibration if necessary regularly during the operation prior to returning the sensor for repair Caution After cleaning rinse the...

Страница 16: ...nu of the transmitter One point calibration Three point calibration Installation adjustment Correction function Adjust calibration data Note Please refer to the Operating Instructions of the Liquisys...

Страница 17: ...lation accessories Immersion assembly holder CYH101 For pH ORP oxygen conductivity assemblies and for oxygen and turbidity sensors Ordering acc to product structure Technical Information TI092C 07 en...

Страница 18: ...ISO 7027 EN 27027 order no 50081264 8 Troubleshooting 8 1 Troubleshooting instructions Troubleshooting must take account of the whole measuring system Transmitter Electrical leads and connectors Asse...

Страница 19: ...ons with the packaging and the transportation documents No repair without completed declaration 8 4 Disposal The device contains electronic components and must therefore be disposed of in accordance w...

Страница 20: ...mum measured error 5 min 0 02 FNU of measured value system measured error related to the primary formazine standard tracing according to ISO 5725 and ISO 7027 EN 27027 Repeatability 1 min 0 01 FNU of...

Страница 21: ...rocess connections G1 and NPT Temperature sensor NTC resistor 30K at 25 C 77 F 10 1 60 122 3 2 4 5 50 20 30 40 C F bar psi 87 70 50 30 20 90 110 40 50 60 130 80 40 60 6 70 104 77 25 15 Sensor carrier...

Страница 22: ...rotection 20 Installation 4 7 Measuring system 12 Installation instructions 11 M Maintenance 15 Materials 21 Maximum measured error 20 Measured value 20 Measured variable 20 Measuring function 15 Meas...

Страница 23: ...__________________________________________ ______________________________________________________________________________________________________________ We hereby certify that this declaration is fil...

Страница 24: ...www endress com worldwide BA176C 07 en 08 07 Printed in Germany FM SGML 6 0 DT 71060783...

Отзывы: