8.1.3
Instrument-specific error
No cleaner conveyance
– Tank empty
– Line blocked
Check error messages.
Test functions in manual operation.
Indicator LEDs CPG30
(see fig. 35 / fig. 36, page 39):
V1
: Additional valve 1 active
Meas
: Assembly in measurement mode
Alive
: LED flashes irregularly, if function
o.k.
Pressure switch feedback (Pos.No. 440,
p. 136) type "active open":
no pressure = closed
with pressure = open.
Assembly stays in
"Service" position
– No compressed air
– Switch to "Maintenance"
– Incorrect position feedback signal
Check error messages
Test functions in manual operation.
Disconnect pressure switch and check with
Ohmmeter.
Assembly stays in
"Measurement" position
– No compressed air
– Switch to "Measurement"
– Incorrect position feedback signal
Assembly permanently
proceeds
Pneumatic hoses to assembly connected
in a wrong way
Check pneumatic hoses.
Assembly proceeds several
times without correct
feedback
– Pneumatic connections interchanged
– Feedback not correctly connected
– Feedback switch is wrongly adjusted
– Assembly has been proceeded
manually. Feedback signal is,
therefore, undefined.
– fig. 29, page 34 or fig. 32, page 36 and
fig. 53, page 139:
Hose 2 "measuring" to valve 5 in front,
hose 3 "service" to valve 5 in the back.
– fig. 29, page 34 or fig. 32, page 36 and
fig. 53, page 139:
Hose 5 "measuring" feedback
(terminals. 11/12), hose 6 "service"
feedback (terminals 13/14)
– Feedback switch under pressure:
opened: Kl. 11/12-13/14 = 14 V
closed: Kl. 11/12-13/14 = 0 V
– Position change via menu manual
operation
Error
Possible cause
Remedial action
Equipment needed, spare
parts
Error
Possible cause
Tests and / or remedial action
Equipment, spare parts,
personnel
Display dark, no LEDs
active
No mains voltage
Check whether mains voltage is applied.
Electrician / e.g. multimeter
Supply voltage incorrect or too low
Compare actual mains voltage with
nameplate rating.
Connection defective
Terminal not picked-up; insulation clamped.
Instrument fuse defective (non-Ex)
Replace fuse after comparing mains voltage
and nameplate rating.
Electrician / suitable fuse; see fig. 49
(p. 135)
Instrument fuse defective (Ex)
Replace fuse.
Use Ex fuse; electrician required
Power unit defective
Replace power unit, pay attention to variant. On-site diagnosis: all 6 red LEDs on the
M3G module must be lit
Central module defective (if all 6 LEDs
on the power unit M3G are lit)
Replace central module.
Pay attention to variant.
On-site diagnosis by responsible service
(test module required)
Ribbon cable loose or defective
Check ribbon cable.
Cable soldered onto the site of the M3G
module
Display dark, but
LED active
Central module defective
(Module: M3Cx-x)
Replace central module M3Cx-x.
On-site diagnosis by responsible service
(test module required)
Display functioning, but no
change in display and/or
instrument cannot be
operated
Instrument or module in instrument not
correctly installed
Check module connections.
See device view on page 135
Operating system in impermissible state
Switch instrument off and on.
Possibly EMC problem: if problem persists,
have installation checked by responsible
service
Содержание Topclean S CPC30
Страница 154: ...10 Technical data Topclean S 154 Endress Hauser...
Страница 156: ...11 Appendix Topclean S 156 Endress Hauser C07 CPC30xxx 19 06 08 en 006 eps...
Страница 157: ...Topclean S 11 Appendix Endress Hauser 157 C07 CPC30xxx 19 06 08 en 007 eps...
Страница 158: ...11 Appendix Topclean S 158 Endress Hauser C07 CPC30xxx 19 06 08 en 008 eps...
Страница 159: ...Topclean S 11 Appendix Endress Hauser 159...
Страница 160: ...11 Appendix Topclean S 160 Endress Hauser C07 CPC30xxx 19 06 08 en 002 eps...
Страница 161: ...Topclean S 11 Appendix Endress Hauser 161 C07 CPC30xxx 19 06 08 en 003 eps...
Страница 162: ...11 Appendix Topclean S 162 Endress Hauser C07 CPC30xxx 19 06 08 en 014 eps...
Страница 163: ...Topclean S 11 Appendix Endress Hauser 163 C07 CPC30xxx 19 06 08 en 015 eps...
Страница 164: ...11 Appendix Topclean S 164 Endress Hauser C07 CPC30xxx 19 06 08 en 011 eps...
Страница 165: ...Topclean S 11 Appendix Endress Hauser 165 C07 CPC300xx 19 06 08 en 010 eps...
Страница 166: ...11 Appendix Topclean S 166 Endress Hauser C07 CPC30xxx 19 06 08 en 012 eps...
Страница 167: ...Topclean S 11 Appendix Endress Hauser 167 C07 CPC30xxx 19 06 08 en 013 eps...
Страница 176: ...Index Topclean S 176 Endress Hauser...
Страница 178: ...www endress com worldwide BA236C 07 en 11 04 51504339 Printed in Germany FM SGML 6 0 DT...