10. Push the retaining slide with the filter element (pos. 5) onto the mounting guide pipe.
11. Put the retaining slide with the filter element down by the chain until the limit stop. Secure
the chain end at the rail.
The complete filter unit has to be below the water level.
3.3.4
Mounting the control box
a0007160
Fig. 8:
Control box dimensions, left front view, right side view
Depending on the version, the control box is delivered with two clips for rail mounting or with four
plastic brackets for wall mounting.
1.
Mount the clips or the brackets at the holes intended for that purpose on the reverse side of
the control box. For this, the clips must be fixed to the upper holes.
2.
Rail mounting:
Screw the clips on the highest, horizontally-running rail pipe, right by the filter station. For the
box to hang straight, the supplied rubber buffer must be attached to the reverse side of the box.
For this, drill a hole with a 4 mm (0.16 inch) diameter in the middle of the box position, on
which a lower horizontal rail pipe is situated. To secure the rubber buffer, use the supplied
Phillips screw.
3.
Wall mounting:
Hold the box with the brackets screwed onto it against the wall and mark the holes. Then drill
the holes and use the supplied anchor pins to secure the box to the wall.
400 (15.8)
327 (12.9)
420
(16.5)
4 x Ø 8.5 (0.33)
400
(15.8)
30 (1.18)
200 (7.87)
mm (inch)
a0007375
Fig. 9:
Wall brackets
a0007376
Fig. 10:
Pipe clamp for rail mounting
Ø48
(1.89)
...
60
(2.36)
M8