Serial Port Communications
Operator’s Manual
3
–
25
•
N-Pentane
: Sets the mole fraction of n-pentane in the dry gas
mixture used when calculating the dew point temperature per ISO
18453:2006. The default value (0.00004) corresponds to the natural
gas mixture NG3.
•
Neo-Pentane
: Sets the mole fraction of neo-pentane in the dry gas
mixture used when calculating the dew point temperature per ISO
18453:2006. The default value (0.00003) corresponds to the
natural
gas mixture NG3.
•
Nitrogen
: Sets the mole fraction of nitrogen in the dry gas mixture
used when calculating the dew point temperature per ISO
18453:2006. The default value (0.00912) corresponds to the natural
gas mixture NG3.
•
Operator Parameter01
to
Operator Parameter20
: Parameter
indices for parameters to be viewed through the Operator Parameter
section.
•
Operator Password
: Sets a password for the Operator Parameter
section.
•
Password
: Required to access the system to download (i.e.,
change) register settings. In Table 3–1 on page 3–15, those registers
denoted as R/W L1 can be modified if the User Level 1 password is
downloaded to this register.
•
Peak Index Ref
: Peak index used for reference.
•
Peak Index Ref Dry
: Peak index (0.0 for non-differential units)
used for reference from the last scrubber cycle.
•
Peak Track Index
: Peak index of the measured spectrum.
•
Peak Track Index Dry
: Peak index (0.0 for non-differential units)
of the measured spectrum from the last scrubber cycle.
•
Peak Tracking
: A software utility that periodically adjusts the laser
current to keep the absorption peak of the measured component at
a known location.
•
Pipeline Pressure
: Sets the pipeline pressure (in mbar) in the
current dew point calculation or, if enabled, displays the current
pipeline pressure input through the AI Pressure Input.
•
ppbv ConvFactor 05
: Sets a custom conversion factor when the
parameter Concentration Unit = 5 (ppbv) and this value is greater
than 0.0. When it is equal to 0.0, the default conversion factor is
used.
•
ppbw ConvFactor 06
: Sets a custom conversion factor when the
parameter Concentration Unit = 6 (ppbw) and this value is greater
than 0.0. When it is equal to 0.0, the default conversion factor is
used.
Содержание SpectraSensors SS2000e
Страница 2: ......
Страница 4: ......
Страница 8: ...NS 5 14 Firmware iv 4900002262 rev B 3 23 21 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 10: ...NS 5 14 Firmware vi 4900002262 rev B 3 23 21 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 12: ...NS 5 14 Firmware viii 4900002262 rev B 3 23 21 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 100: ...NS 5 14 Firmware 4 10 4900002262 rev B 3 23 21 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 106: ...NS 5 14 Firmware A 6 4900002262 rev B 3 23 21 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 112: ...NS 5 14 Firmware Index 6 4900002262 rev A 3 23 21 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 113: ......
Страница 114: ...www spectrasensors com contact 4900002262 Rev B...