background image

Diagnostics and troubleshooting

Solitrend MMP42

24

Hauser

8.4  

Settings

8.4.1  

Material calibration

Different calibrations are saved in the sensor depending on the intended application of the

sensor.
In the "Material calibration" menu item, the necessary calibration can be selected via the

optional remote display, depending on the application. In this way, one sensor can cover a

variety of applications.
It is also possible to perform your own calibrations and overwrite an existing calibration curve.

SD02333M 

remote display

 - description of operation and material calibration.

8.5  

Special functions

Special functions that are available are described in the Operating Instructions pertaining to

the device.

9  

Diagnostics and troubleshooting

9.1  

Optimizing the material flow

For accurate measurement results, certain limits must be respected with regard to the

installation and environmental conditions, and the associated bulk density of the material

being measured. Furthermore, there must be a sufficiently thick layer of material covering the

sensor.
If the material flow is too fast, the level of material above the surface of the sensor can be too

low. A hopper chute with guide plates can concentrate and increase the level of material

above the sensor head. Ideally - particularly in the case of wet sand - the guide plates have a

PTFE coating so that no material can stick to them. The sensor requires a layer of material of

at least 60 mm (2.36 in). There are installations where the amount of material is too low or

too spread out to ensure sufficient material flow over the sensor. In such cases it may be

necessary to "concentrate" the material flow so that material accumulates above the sensor as

it flows. The diagram below shows an example of a possible unit where the material is

concentrated at the side of the sensor and above the sensor.

Содержание Solitrend MMP42

Страница 1: ...structions they are not a substitute for the Operating Instructions pertaining to the device For detailed information refer to the Operating Instructions and other documentation Available for all devi...

Страница 2: ...Solitrend MMP42 2 Endress Hauser Order code Ext ord cd Ser no www endress com deviceviewer Endress Hauser Operations App XXXXXXXXXXXX XXXXX XXXXXX XXX XXXX XX Serial number 1 3 2 A0023555...

Страница 3: ...llation 9 5 1 Installation conditions 9 5 2 Round sensor short middle 9 5 3 Rectangular sensor 11 5 4 Protection of sensor connector against abrasion 13 5 5 Electronics housing sensor temperature rang...

Страница 4: ...rts you to a dangerous situation Failure to avoid this situation can result in minor or medium injury NOTICE This symbol contains information on procedures and other facts which do not result in perso...

Страница 5: ...the manual and supplementary documentation as well as the certificates depending on the application Personnel must follow instructions and comply with general policies The operating personnel must ful...

Страница 6: ...he medium temperature Danger of burns from contact with surfaces In the event of elevated medium temperatures ensure protection against contact to prevent burns 2 3 Workplace safety For work on and wi...

Страница 7: ...s and media with material density ratings of 0 3 to 1 0 kg dm3 and conductivity values up to 2 mS cm 3 1 Product design 1 2 3 1 2 3 1 2 3 A0040209 1 Product design 1 Measuring cell wave guide 1 4301 c...

Страница 8: ...itions is not met please contact the manufacturer s sales office 4 2 Product identification The following options are available for the identification of the measuring device Nameplate specifications...

Страница 9: ...should be created or structural measures may be needed at the place of installation to ensure that the material flow and therefore the material density over the sensor is relatively constant The meas...

Страница 10: ...ounting flange 3 Round sensor The mounting flange for the round sensor short or middle version can be mounted on the bottom or on the side wall of the container 86 3 39 86 3 39 132 5 2 150 6 0 108 4 2...

Страница 11: ...e holes and the cut out for the sensor in the container 1 Check the fit between the sensor and mounting flange 2 Make the cut out in the container 20 0 79 8 0 31 6 A0044393 4 Mounting position mountin...

Страница 12: ...2 Endress Hauser 5 3 1 Dimensions 45 1 77 36 1 42 90 3 54 135 5 31 8 5 0 33 12 5 0 49 15 0 59 47 5 1 87 40 1 57 25 0 98 60 2 36 7 5 0 3 7 5 0 3 120 4 72 15 0 59 A0037426 5 Dimensions of rectangular se...

Страница 13: ...plate it is recommended to mount an additional protective guard on the sensor connector 1 The heat shrink tube supplied with the cable can be used to provide this protection A0037427 6 Example of roun...

Страница 14: ...und cable can be protected with a silicone tube not included in the delivery A0037429 8 Example of round sensor 5 5 Electronics housing sensor temperature range up to 120 C 248 F The electronics housi...

Страница 15: ...ost installation check Perform the following checks after mounting the device Is the device undamaged visual inspection If provided are the measuring point number and labeling correct Are the connecti...

Страница 16: ...rs 6 2 0 25 mm2 PUR sheath resistant to oils and chemicals Rectangular sensors Standard lengths fixed cable 5 m 16 ft Cable lengths of 1 to 100 m 3 to 328 ft are possible upon request UNITRONIC PUR CP...

Страница 17: ...s RT Wire color gray GY pink PK J IMP Bus COM Wire color blue BU red RD K 2nd analog positive Wire color pink PK E 2nd analog return line Wire color gray GY H Shield is grounded at the sensor The inst...

Страница 18: ...al moisture Wire color green GN 1st analog return line material moisture Wire color yellow YE IMP Bus RT Wire color pink PK IMP Bus COM Wire color gray GY 2nd analog positive Wire color blue BU 2nd an...

Страница 19: ...for measured value output The measured values are output as a current signal via the analog output The sensor can be set to 0 to 20 mA or 4 to 20 mA Output 1 can be scaled at the factory or can be sub...

Страница 20: ...llowing possible options Moisture temperature Output 1 for moisture output 2 for material temperature Moisture conductivity Output 1 for moisture output 2 for conductivity in the range from 0 to 20 mS...

Страница 21: ...ut CA mode Cyclic Average Filter Standard averaging for relatively fast but continuous measurement processes with simple filtering and an accuracy of up to 0 1 The CA operating mode is also used to re...

Страница 22: ...ation E Barley without temperature compensation F Wheat maize rye without temperature compensation G Soy with temperature compensation at 60 C 140 F H Rape and oilseeds K Cal14 air water 0 to 100 The...

Страница 23: ...readings at the discharge point the calibration curve must be correctly set and fine adjusted Once the device is fine adjusted for all possible types of grain these parameters are stored in the device...

Страница 24: ...s must be respected with regard to the installation and environmental conditions and the associated bulk density of the material being measured Furthermore there must be a sufficiently thick layer of...

Страница 25: ...t offset measuring range etc Please contact the PLC manufacturer for more information With the remote display a fine adjustment or parallel shift in the sensor can be performed using the Offset parame...

Страница 26: ...ontact the PLC manufacturer for more information Due to inaccurate data processing it may be necessary to check the moisture value displayed in the PLC For this purpose connect the sensor to the remot...

Страница 27: ......

Страница 28: ...www addresses endress com 71510190 71510190...