3.3.1
Turning the transmitter housing
Turning the aluminium field housing
#
Warning!
The rotating mechanism for devices for hazardous areas Zone 1 (ATEX) or Class I Div. 1 (FM/CSA)
is different to that described here. The procedure for turning these housings is described in the
Ex-specific documentation.
1.
Loosen the two securing screws.
2.
Turn the bayonet catch as far as it will go.
3.
Carefully lift the transmitter housing as far as it will go.
4.
Turn the transmitter housing to the desired position (max. 2 x 90° in either direction).
5.
Lower the housing into position and re-engage the bayonet catch.
6.
Retighten the two securing screws (only Hauser screws to be used).
a0004302
Fig. 16:
Turning the transmitter housing (aluminium field housing)
3.3.2
Installing the wall-mount transmitter housing
There are various ways of installing the wall-mount transmitter housing:
• Mounted directly on the wall
• Installation in control panel
Page 26 (separate mounting set, accessories
• Pipe mounting
Page 27 (separate mounting set, accessories
"
Caution!
• Make sure that ambient temperature does not go beyond the permissible range of
– 20 °C to +60 °C (–2 °F to +140 °F), optional – 40 °C to +60 °C (–40 °F to +140 °F).
Install the device in a shaded location. Avoid direct sunlight.
• Always install the wall-mount housing in such a way that the cable entries are pointing down.