Commissioning
Proline Prowirl F 200 PROFIBUS PA
86
Hauser
Parameter
Prerequisite
Description
Selection / User
entry
Factory setting
Reference pressure
The following conditions are
met:
• Order code for "Sensor
version",
Option "Mass (integrated
temperature measurement)"
• The
Gas
option is selected in
the
Select medium
parameter parameter.
Enter reference pressure for
the calulation of the reference
density.
Dependency
The unit is taken from the
Pressure unit
parameter.
0 to 250 bar
1.01325 bar
Reference temperature
The following conditions are
met:
• The
Gas
option is selected in
the
Select medium
parameter.
Or
• The
Liquid
option is
selected in the
Select
medium
parameter.
Enter reference temperature
for calculating the reference
density.
Dependency
The unit is taken from the
Temperature unit
parameter
–200 to 450 °C
20 °C
Reference Z-factor
In the
Select gas type
parameter, the
User-specific
gas
option is selected.
Enter real gas constant Z for
gas under reference
conditions.
0.1 to 2
1
Linear expansion coefficient
The following conditions are
met:
• The
Liquid
option is
selected in the
Select
medium
parameter.
• The
User-specific liquid
option is selected in the
Select liquid type
parameter.
Enter linear, medium-specific
expansion coefficient for
calculating the reference
density.
1.0 · 10
-6
to 2.0 · 10
-3
2.06 · 10
-4
Relative density
The following conditions are
met:
• In the
Select medium
parameter, the
Gas
option is
selected.
• In the
Select gas type
parameter, the
Natural gas
option is selected.
• In the
Density calculation
parameter, the
ISO 12213-
3
option is selected.
Enter a relative density of the
natural gas.
0.55 to 0.9
0.664
Specific heat capacity
The following conditions are
met:
• Selected medium:
– In the
Select gas type
parameter, the
User-
specific gas
option is
selected.
Or
– In the
Select liquid type
parameter, the
User-
specific liquid
option is
selected.
• In the
Enthalpy type
parameter, the
Heat
option
is selected.
Enter the specific heat capacity
of the medium.
Dependency
The unit is taken from the
Specific heat capacity unit
parameter
0 to 50 kJ/(kgK)
4.187 kJ/(kgK)
Содержание Proline Prowirl F 200