Write protection and simulation
Write protection of the device parameters and simulation in the Analog Input and Discrete Output
function block can be locked or unlocked via a jumper setting on the FOUNDATION Fieldbus
I/O board (
→
Operating Instructions for Proline Promag 55 FOUNDATION Fieldbus, BA126D).
The parameter WRITE_LOCK shows the status of the hardware write protection. The following
statuses are possible:
The parameter BLOCK_ERR indicates whether a simulation is possible in the Analog Input and
Discrete Output function block.
2.4
Alarm detection and processing
Process alarms provide information on particular block statuses and block events. The status of the
process alarms is communicated to the fieldbus host system via the parameter BLOCK_ALM. The
parameter ACK_OPTION specifies whether an alarm must be acknowledged via the fieldbus host
system.
The following process alarms are generated by the Resource Block:
Block process alarms
The following block process alarms of the Resource Block are shown via the parameter
BLOCK_ALM:
Write protect process alarm
If write protection is disabled on the FOUNDATION Fieldbus I/O board, then prior to
communicating the change of status to the fieldbus host system the alarm priority specified in the
parameter WRITE_PRI is checked. The alarm priority specifies the action taken when the write
protection alarm WRITE_ALM is enabled.
!
Note!
• If the option of a process alarm has
not
been enabled in the parameter ACK_OPTION, this process
alarm only has to be acknowledged in the parameter BLOCK_ALM.
• The parameter ALARM_SUM shows the current status of all the process alarms.
– LOCKED
= Device data cannot be modified by means of the FOUNDATION
Fieldbus interface.
– NOT LOCKED
= Device data can be modified by means of the FOUNDATION
Fieldbus interface.
– Simulation Active
= Simulation possible in the Analog Input function block via the
SIMULATE parameter and in the Discrete Output function block via
the SIMULATE_D parameter.
– OUT OF SERVICE
– SIMULATE ACTVE
Содержание Proline Promag 55
Страница 60: ...8 Block SUPERVISION Device Functions Proline Promag 55 FOUNDATION Fieldbus 60 Endress Hauser ...
Страница 66: ...10 Index local operation Device Functions Proline Promag 55 FOUNDATION Fieldbus 66 Endress Hauser ...
Страница 68: ...Table of contens FOUNDATION Fieldbus Device Functions Proline Promag 55 FOUNDATION Fieldbus 68 Endress Hauser ...
Страница 129: ...Device Functions Proline Promag 55 FOUNDATION Fieldbus Endress Hauser 129 ...
Страница 130: ...www endress com worldwide BA127D 06 en 09 06 71032705 FM SGML 6 0 ...