Technical data
Proline Promag 55 PROFIBUS PA
124
Hauser
Pressure tightness (lining)
Resistance to partial vacuum in SI units [mbar]
Pressure tightness in US units [psia = pounds/inch
2
]
Promag S
Nominal
diameter
Measuring tube
lining
Resistance of measuring tube lining to partial vacuum (SI units)
Limit values for abs. pressure [mbar] at various fluid temperatures
[mm]
25 °C
50 °C
80° C
100 °C
130 °C
150 °C
180 °C
25 to 600
Polyurethane
0
0
-
-
-
-
-
65 to 600
Natural rubber
0
0
-
-
-
-
-
65 to 600
Hard rubber
0
0
0
–
–
–
–
Promag S
Nominal
diameter
Measuring tube
lining
Resistance of measuring tube lining to partial vacuum (SI units)
Limit values for abs. pressure [mbar] at various fluid temperatures
[mm]
25 °C
80° C
100 °C
130 °C
150 °C
180 °C
15
PTFE
0
0
0
100
–
–
25
PTFE / PFA
0/0
0/0
0/0
100/0
–/0
–/0
32
PTFE / PFA
0/0
0/0
0/0
100/0
–/0
–/0
40
PTFE / PFA
0/0
0/0
0/0
100/0
–/0
–/0
50
PTFE / PFA
0/0
0/0
0/0
100/0
–/0
–/0
65
PTFE / PFA
0/0
*
40/0
130/0
–/0
–/0
80
PTFE / PFA
0/0
*
40/0
130/0
–/0
–/0
100
PTFE / PFA
0/0
*
135/0
170/0
–/0
–/0
125
PTFE / PFA
135/0
*
240/0
385/0
–/0
–/0
150
PTFE / PFA
135/0
*
240/0
385/0
–/0
–/0
200
PTFE / PFA
200/0
*
290/0
410/0
–/0
–/0
250
PTFE
330
*
400
530
–
–
300
PTFE
400
*
500
630
–
–
350
PTFE
470
*
600
730
–
–
400
PTFE
540
*
670
800
–
–
450
PTFE
Partial vacuum is impermissible
500
PTFE
600
PTFE
* No value can be quoted.
Promag H
Nominal
diameter
Measuring tube
lining
Resistance of measuring tube lining to partial vacuum (SI units)
Limit values for abs. pressure [mbar] at various fluid temperatures
[mm]
25 °C
80 °C
100 °C
130 °C
150 °C
180 °C
2 to 100
PFA
0
0
0
0
0
0
Promag S
Nominal
diameter
Measuring tube
lining
Resistance of measuring tube lining to partial vacuum (US units)
Limit values for abs. pressure [mbar] at various fluid temperatures
[inch]
77 °F
122 °F
176 °F
212 °F
266 °F
302 °F
356 °F
1 to 24"
Polyurethane
0
0
-
-
-
-
-
3 to 24"
Natural rubber
0
0
-
-
-
-
-
3 to 24"
Hard rubber
0
0
0
–
–
–
–