Technical data
Promag 50
114
Hauser
Promag H
• 2 measuring electrodes for signal detection
• 1 EPD electrode for empty pipe detection (apart from DN 2 to 15)
Process connections
Promag D
Wafer version
without process connections
Promag L
Flange connections:
• EN 1092-1 (DIN 2501)
– DN
300 = Form A
– DN
350 = Form B
• ANSI
• AWWA
• AS
Promag W and P
Flange connections:
• EN 1092-1 (DIN 2501)
– DN
300 = form A
– DN
350 = flat face
– DN 65 PN 16 and DN 600 PN 16 only as per EN 1092-1
• ANSI
• AWWA (only Promag W)
• JIS
• AS
Promag H
With O-ring:
• Weld nipple DIN (EN), ISO 1127, ODT/SMS
• Flange EN (DIN), ANSI, JIS
• Flange made of PVDF EN (DIN), ANSI, JIS
• External thread
• Internal thread
• Hose connection
• PVC adhesive fitting
With gasket seal:
• Weld nipple DIN 11850, ODT/SMS
• Clamp ISO 2852, DIN 32676, L14 AM7
• Threaded joint DIN 11851, DIN 11864-1, ISO 2853, SMS 1145
• Flange DIN 11864-2
Surface roughness
All data relate to parts in contact with fluid.
• Liner
PFA:
0.4
μ
m (15
μ
in)
• Electrodes: 0.3 to 0.5
μ
m (12 to 20
μ
in)
• Process connection made of stainless-steel (Promag H):
0.8
μ
m (31
μ
in)
10.1.11 Human interface
Display elements
• Liquid crystal display: illuminated, two-line, 16 characters per line
• Custom configurations for presenting different measured-value and status variables
• 2 totalizers
!
Note!
At ambient temperatures below –20 (–4 °F) the readability of the display may be impaired.
Содержание Proline Promag 50
Страница 2: ......
Страница 120: ...Promag 50 Index 120 Endress Hauser ...
Страница 122: ...www endress com worldwide BA00046D 06 EN 14 11 71136623 FM SGML6 0 ProMoDo ...