Proline Cubemass 300 Modbus RS485
Description of device parameters
Hauser
97
Factory setting
1
Additional information
Description
Corrected value = (factor × value) + offset
Density offset
Navigation
Expert → Sensor → Sensor adjustm. → Variable adjust → Density offset (1848)
Description
Use this function to enter the zero point shift for the density trim. The density unit on
which the shift is based is kg/m³.
User entry
Signed floating-point number
Factory setting
0 kg/m³
Additional information
Description
Corrected value = (factor × value) + offset
Density factor
Navigation
Expert → Sensor → Sensor adjustm. → Variable adjust → Density factor (1849)
Description
Use this function to enter a quantity factor for the density. This multiplication factor is
applied over the density range.
User entry
Positive floating-point number
Factory setting
1
Additional information
Description
Corrected value = (factor × value) + offset
Corr. vol offset
Navigation
Expert → Sensor → Sensor adjustm. → Variable adjust → Corr. vol offset (1866)
Description
Use this function to enter the zero point shift for the corrected volume flow trim. The
corrected volume flow unit on which the shift is based is 1 Nm³/s.
User entry
Signed floating-point number
Factory setting
0 Nm³/s