Proline Promag 53 PROFIBUS DP/PA
Wiring
Hauser
55
Cable termination on the remote version
Promag W / Promag P
Terminate the signal and coil current cables as shown in the figure below (Detail A).
Fit the fine-wire cores with wire end ferrules (Detail B).
"
Caution!
When fitting the connectors, pay attention to the following points:
•
Signal cable
→
Make sure that the wire end ferrules do not touch the wire shield on the sensor side.
Minimum distance = 1 mm (exception “GND” = green cable)
•
Coil current cable
→
Insulate one core of the three-core cable at the level of the core reinforcement; you only need two cores for the connection.
TRANSMITTER
Signal cable
Coil current cable
a0002643
a0002644
SENSOR
Signal cable
Coil current cable
a0002646
a0002645
m
= Red cable sleeve, Ø 1.0 mm
n
= White cable sleeve, Ø 0.5 mm
* = Stripping for armored cables only