Oxymax W COS71

Hauser

3

Input

Measured variable

dissolved oxygen [mg/l, ppm, % SAT or hPa]

Measuring range

with Liquisys M COM223/253-WX/WS:
0.001 to 20.000 mg/l
0.0 to 200.0 % SAT
0 to 400 hPa

Wiring

Electrical connection

Direct connection to the transmitter (field device)

Connect the sensor directly to the transmitter (COM253-WX/WS) by using the special measuring cable with 
SXP plug.

Direct connection to the transmitter (panel mounting device)

• Remove the SXP connector (transmitter side!) from the cable.
• Refer to the following table for the cable assignment and the assigned terminals for 

Liquisys M COM223-WX/WS.

• Please note that the cable assignment changes depending on the sensor version (fixed cable or TOP68 

connection).

a0004118

SXP plug

Terminal 
COM223

Sensor with fixed cable (OMK)

Sensor with TOP68 connection 
(CYK71)

Core

Assignment

Core

Assignment

87

YE

+U

B

YE

+U

B

0

GY

0 V

WH

0 V

96

PK

NTC (analog) or Com. (digital)

GN

Communication (digital)

97

BU

NTC (analog) or Com. (digital)

BN

Communication (digital)

88

BN

–U

B

Koax innen –U

B

19

GN

Alarm

18

WH

Sensor signal

Содержание Oxymax W COS71

Страница 1: ...itions Laboratory measurement vs continuous process monitoring Spot laboratory measurements to measure oxygen involve a risk of error due to sampling errors Continuous measurement directly in the proc...

Страница 2: ...er bromide or silver chloride coating on the anode uses up the bromide or chloride ions dissolved in the electrolyte In the case of conventional membrane covered sensors working with the two electrode...

Страница 3: ...el mounting device Remove the SXP connector transmitter side from the cable Refer to the following table for the cable assignment and the assigned terminals for Liquisys M COM223 WX WS Please note tha...

Страница 4: ...g l 0 001 ppm Maximum measured error 1 of measured value2 Long term drift with permanent polarization 1 per month Influence of medium pressure Pressure compensation not necessary Polarization time 60...

Страница 5: ...ensors You will find them in the Operating Instructions for the assembly used Environment Ambient temperature range 5 to 50 C 20 to 120 F Storage temperature filled with electrolyte 5 to 50 C 20 to 12...

Страница 6: ...plug in connection 0 3 kg 0 66 lbs Material Process connection G1 Maximum cable length max 100 m 328 ft including cable extension Membrane thickness approx 25 m Electrolyte Alkaline electrolyte a0004...

Страница 7: ...Flow assembly COA260 for plate or wall mounting for oxygen trace measurements ordering acc to product structure Technical Information TI310C 07 en Zero solution 3 units to produce 3 x 1 liter oxygen...

Страница 8: ...le Ordering acc to product structure see Technical Information TI 199C 07 en Instruments International Endress Hauser Instruments International AG Kaegenstrasse 2 4153 Reinach Switzerland Tel 41 61 71...

Отзывы: