Tankside Monitor NRF81
Operating menu
Hauser
207
Manual density
Navigation
Setup → Advanced setup → Application → Tank calculation → HTG → Manual
density
Description
Defines the manual density.
User entry
0 to 3
000 kg/m³
Factory setting
800 kg/m³
Additional information
Read access
Maintenance
Write access
Maintenance
Minimum level
Navigation
Setup → Advanced setup → Application → Tank calculation → HTG → Minimum level
Description
Defines the minimum level below which no HTG calculation will take place.
User entry
0 to 20
000 mm
Factory setting
7
000 mm
Additional information
Read access
Operator
Write access
Maintenance
Minimum pressure
Navigation
Setup → Advanced setup → Application → Tank calculation → HTG → Minimum
pressure
Description
Defines the minimum pressure below which no HTG calculation takes place.
User entry
0 to 100 bar
Factory setting
0.1 bar
Additional information
Read access
Operator
Write access
Maintenance