11.12 Firmware history
Date
Version
Changes to firmware
Documentation
10/2022 01.12.01 Improvement
Simple transmission of bottle position and bottle level via
the fieldbus
BA00443C/07/EN/26.22
BA00478C/07/EN/11.22
BA01407C/07/EN/08.22
04/2021 01.09.00 Improvement
• Signal type at binary input to control program events
• Possible to reset counters when sampling programs are
paused
BA00443C/07/EN/25.21
BA00478C/07/EN/10.21
BA00479C/07/EN/23.21
BA01407C/07/EN/07.21
05/2018 01.06.06 Extension
Heartbeat Monitoring and Verification
Improvement
• New soft keys
ALL
and
NONE
in multiple choice editors
• Manual factor for CAS51D nitrate
• Calibration timer and validity revised for pH, conductivity,
oxygen and disinfection
• Clear distinction between offset and 1-point calibration
for pH
• Heartbeat verification report can now also be downloaded
via the web server
• Better description of diagnostics code 013
BA00444C/07/EN/22.18
03/2016 01.06.00 Extension
• "Ensure activation" switch with subprogram activation
"Interval" ("Bavarian sampling")
• Binary input can switch sampling to the hold state
Improvement
• Sensors can be calibrated while the program is running
• Incremental sampling moved after diagnostics/device test
• Dosing time for vacuum sampling can be adjusted
• Binary output can be switched after multiple samples
have been taken
• Improved control over the activation/deactivation of
subprograms via binary inputs
• Specification of "Volume per bottle" in the run screen
• Program can be started at a specific time
• Paused program can be restarted with new "Continue
program" entry via MODE soft key
• Minimum sampling time and dosing time reduced to 1 s
for in-line sampling
BA00444C/07/EN/19.16
BA00486C/07/EN/02.13
BA01245C/07/EN/03.16
12/2013 01.05.00 Extension
• Chemoclean Plus
• Calendar function for cleaning
• Conductivity:
• Measuring range switching also for conductive
conductivity measurement
• External temperature signal via current input
• Oxygen:
• External pressure or temperature signals via current
input
• Connected conductivity sensor can be used to calculate
the salinity
• SAC, nitrate, turbidity:
Calibration settings can be configured via fieldbus
• Channel-specific diagnostics codes for HOLD function.
Improvement
• Web server login for managing multiple users
• Set point and PID parameters for controllers can be
configured via fieldbus
BA00444C/07/EN/17.13
BA01225C/07/EN/02.13
BA00486C/07/EN/02.13
BA01245C/07/EN/01.13