Mounting
Levelflex FMP56, FMP57 FOUNDATION Fieldbus
36
Hauser
Non-metallic vessels
1
2
A0012527
1
Non-metallic vessel
2
Metal sheet or metal flange
To ensure reliable measurements in non-metallic vessels:
• Select an instrument version with metal flange (minimum size DN50/2").
• Or: mount a metal sheet with a diameter of at least 200 mm (8 in) to the probe at the
process connection. Its orientation must be perpendicular to the probe.