Levelflex FMP56, FMP57 FOUNDATION Fieldbus
Important document information
Hauser
11
Feature 010 Approval
Available for
Feature 020: "Power Supply; Output"
A
B
C
E
/G
K
I3
IEC Ex d [ia] IIC T6 Ga/Gb, Ex t IIIC Da/Db
• FMP56
• FMP57
XA00503F XA00503F XA00503F XA00523F XA01136F
KA
KC Ex ia IIC T6 Ga
• FMP56
• FMP57
XA01169F -
XA01169F -
-
KB
KC Ex ia IIC T6 Ga/Gb
• FMP56
• FMP57
XA01169F -
XA01169F -
-
MA
INMETRO Ex ia IIC T6 Ga
• FMP56
• FMP57
XA01038F XA01038F XA01038F -
XA01038F
ME
INMETRO Ex t IIIC Da
• FMP56
• FMP57
XA01043F XA01043F XA01043F -
XA01043F
MH
INMETRO Ex ic IIC T6 Gc
• FMP56
• FMP57
XA01040F XA01040F XA01040F -
XA01040F
NA
NEPSI Ex ia IIC T6 Ga
• FMP56
• FMP57
XA00634F XA00634F XA00634F XA00640F XA00634F
NB
NEPSI Ex ia IIC T6 Ga/Gb
• FMP56
• FMP57
XA00634F XA00634F XA00634F XA00640F XA00634F
NF
NEPSI DIP A20/21 T85…90oC IP66
• FMP56
• FMP57
XA00637F XA00637F XA00637F XA00643F XA00637F
NG
NEPSI Ex nA II T6 Gc
• FMP56
• FMP57
XA00635F XA00635F XA00635F XA00641F XA00635F
NH
NEPSI Ex ic IIC T6 Gc
• FMP56
• FMP57
XA00635F XA00635F XA00635F XA00641F XA00635F
N2
NEPSI Ex ia IIC T6 Ga/Gb, Ex iaD 20/21 T85…90°C
• FMP56
• FMP57
XA00638F XA00638F XA00638F XA00644F XA00638F
N3
NEPSI Ex d[ia] IIC T6 Ga/Gb, DIP A20/21 T85…90°C
IP66
• FMP56
• FMP57
XA00639F XA00639F XA00639F XA00645F XA00639F
8A
FM/CSA IS+XP Cl.I,II,III Div.1 Gr.A-G
• FMP56
• FMP57
XA00531F
XA00532F
XA00531F
XA00532F
XA00531F
XA00532F
XA00572F
XA00573F
XA00531F
XA00532F
1)
A: 2-wire; 4-20mA HART
2)
B: 2-wire; 4-20mA HART, switch output
3)
C: 2-wire; 4-20mA HART, 4-20mA
4)
E: 2-wire; FOUNDATION Fieldbus, switch output
5)
G: 2-wire; PROFIBUS PA, switch output
6)
K: 4-wire 90-253VAC; 4-20mA HART
7)
L: 4-wire 10,4-48VDC; 4-20mA HART
For certified devices the relevant Safety Instructions (XA) are indicated on the
nameplate.
Содержание Levelflex FMP56
Страница 210: ...www addresses endress com 71344087 71344087 ...