Levelflex FMP55 HART
Operating menu
Hauser
155
Intermediate height
Navigation
Setup → Advanced setup → Linearization → Intermediate height
Prerequisite
Linearization type (→ 151)
has one of the following values:
• Pyramid bottom
• Conical bottom
• Angled bottom
Description
Height of the pyramid, conical or angled bottom.
User entry
0 to 200 m
Factory setting
0 m
Additional information
0%
H
A0013264
H
Intermediate height
The unit is defined in the
Distance unit
Table mode
Navigation
Setup → Advanced setup → Linearization → Table mode
Prerequisite
Linearization type (→ 151)
=
Table
Description
Select editing mode of the linearization table.
Selection
• Manual
• Semiautomatic
• Clear table
• Sort table
Factory setting
Manual