Electrical connection
iTEMP TMT82
18
Hauser
Sensor input 1
RTD or resistance
transmitter, 4-wire
-
-
-
-
Thermocouple (TC),
voltage transmitter
5.3.1
Connecting to push-in terminals
2.
3.
4.
5.
1.
2.
3.
A
B
C
A0039468
11
Push-in terminal connection, using the example of a head transmitter
Fig. A, solid wire:
1. Strip wire end. Min. stripping length 10 mm (0.39 in).
2. Insert the wire end into the terminal.
3. Pull the wire gently to ensure it is connected correctly. Repeat from step 1 if necessary.
Fig. B, fine-strand wire without ferrule:
1. Strip wire end. Min. stripping length 10 mm (0.39 in).
2. Press down on the lever opener.
3. Insert the wire end into the terminal.
4. Release lever opener.
5. Pull the wire gently to ensure it is connected correctly. Repeat from step 1 if necessary.