TMT180
Maintenance
Hauser
15
Customer-specific linearization
Customer-specific linearization and sensor matching are activated after the
POLYNOM RTD
sensor type is selected. Please find detailed information about linearization in the PC configuration
software.
7
Maintenance
The temperature transmitter has no moving parts and requires minimal scheduled maintenance.
Sensor Checkout
To determine whether the sensor is at fault, replace it with another sensor or connect a test sensor
locally at the transmitter to test remote sensor wiring. Select any standard, off-the-shelf sensor for
use with a temperature head transmitter, or consult the factory for a replacement special sensor or
transmitter combination.
8
Accessories
Service functions
Output simulation
Activate simulation mode.
Input:
•
OFF
• ON
Input of the simulation value (current).
Input: 3.8 to 20.5 mA
Configurable parameters (Default settings in bold)
Configuration set for PC SETUP (SETUP
program and PC serial interface cable:
→
Order No.: TMT180A-VM (TTL/RS 232C)
→
Order No.: TXU10-AB (TTL/USB).
ReadWin
®
2000, DIN rail clip (SONDTT-AF)
according to IEC 60715 for E+H temperature
head transmitters, Field housing TAF 10 suitable
for E+H temperature head transmitters.
PC SETUP program can be downloaded free of
charge from the internet from the following
address:
www.readwin2000.com
Please contact your supplier when ordering (e.g.
spare parts)!