background image

Incoming acceptance and product identification

iTEMP TMT142B

6

Hauser

NOTICE

The device may only be powered by a power unit with an energy-limited circuit in

accordance with UL/EN/IEC 61010-1, Section 9.4 and the requirements of Table 18.

3  

Incoming acceptance and product identification

3.1  

Incoming acceptance

1. Unpack the temperature transmitter carefully. Is the packaging or content damaged?

 Damaged components may not be installed as the manufacturer can otherwise not

guarantee compliance with the original safety requirements or the material

resistance, and can therefore not be held responsible for any resulting damage.

2. Is the delivery complete or is anything missing? Check the scope of delivery against your

order.

3. Does the nameplate match the ordering information on the delivery note?
4. Are the technical documentation and all other necessary documents provided? If

applicable: are the Safety Instructions (e.g. XA) for hazardous areas provided?

If one of these conditions is not satisfied, contact the Hauser Sales Center.

3.2  

Product identification

The following options are available for identification of the device:

• Nameplate specifications

• Extended order code with breakdown of the device features on the delivery note

• Enter the serial number from the nameplate in the 

W@M Device Viewer

(

www.endress.com/deviceviewer

): all data relating to the device and an overview of the

Technical Documentation supplied with the device are displayed.

• Enter the serial number on the nameplate into the 

Hauser Operations App

 or scan

the 2-D matrix code (QR code) on the nameplate with the 

Hauser Operations App

:

all the information about the device and the technical documentation pertaining to the

device is displayed.

Содержание HART iTEMP TMT142B

Страница 1: ...g Instructions they are not a substitute for the Operating Instructions pertaining to the device For detailed information refer to the Operating Instructions and other documentation Available for all...

Страница 2: ...iTEMP TMT142B 2 Endress Hauser Order code Ext ord cd Ser no www endress com deviceviewer Endress Hauser Operations App XXXXXXXXXXXX XXXXX XXXXXX XXX XXXX XX Serial number 1 3 2 A0023555...

Страница 3: ...6 Post connection check 16 6 Operation options 17 6 1 Overview of operation options 17 6 2 Transmitter configuration 18 6 3 Access to the operating menu via the SmartBlue App 18 7 Commissioning 19 7 1...

Страница 4: ...avoid this situation can result in minor or medium injury NOTICE This symbol contains information on procedures and other facts which do not result in personal injury 1 3 Tool symbols Symbol Meaning A...

Страница 5: ...one sensor input for a resistance thermometer RTD thermocouples TC resistance and voltage transmitters The device is designed for installation in the field If the device is used in a manner not speci...

Страница 6: ...g information on the delivery note 4 Are the technical documentation and all other necessary documents provided If applicable are the Safety Instructions e g XA for hazardous areas provided If one of...

Страница 7: ...utput current consumption device revision firmware and hardware version degree of protection 1 4 Radio approval Bluetooth optional depending on the configuration 1 5 2 lines for the TAG name 1 6 Appro...

Страница 8: ...cates and approvals must be observed please see Ex certificates 4 1 2 Important ambient conditions Ambient temperature Without display 40 to 85 C 40 to 185 F With display 40 to 80 C 40 to 176 F With o...

Страница 9: ...and of the fieldbus transmitter housing into the connection compartment 4 Fit the field transmitter with the insert on the thermowell 1 5 Mount the fieldbus shielded cable or fieldbus connector 6 on t...

Страница 10: ...unting or with a 2 pipe mounting bracket 316L see the Accessories section Dimensions in mm in 4 3 Post installation check After installing the device carry out the following checks Device condition an...

Страница 11: ...ntact the supplier if you have any questions Do not occupy the display connection An incorrect connection can destroy the electronics NOTICE Do not overtighten the screw terminals as this could damage...

Страница 12: ...SD electrostatic discharge Protect the terminals from electrostatic discharge Failure to observe this may result in the destruction or malfunction of parts of the electronics Terminal assignment 3 3 3...

Страница 13: ...not have additional potential equalization mains frequency equalizing currents can occur that damage the cable or the shielding In such cases the shielding of the fieldbus cable is to be grounded on o...

Страница 14: ...shed by the HART FieldComm Group particularly HCF LIT 20 HART a technical summary TMT142B FieldCare DeviceCare HART Modem PLC 200 3 2 250 PMC731 PIC0001 Online 1 Group Select 2 PV 0 7 bar HELP SEND HO...

Страница 15: ...unding of the cable shield at one end 4 Optional grounding of the field device isolated from cable shielding 5 4 Special connection instructions If the device is fitted with a surge arrester module th...

Страница 16: ...they enter the cable glands water trap This means that any moisture that may form cannot enter the gland Install the device in such a way that the cable glands are not facing upwards 8 16 Replace unu...

Страница 17: ...essary remove the display with the fitting kit from the electronics module 4 Configure the Bluetooth function accordingly using the DIP switch In general the following applies switch to ON function en...

Страница 18: ...s technology Signal transmission via Bluetooth wireless technology uses a cryptographic technique tested by the Fraunhofer Institute The device is not visible via Bluetooth wireless technology without...

Страница 19: ...hrough the various items of information about the device swipe the screen to the side 7 Commissioning 7 1 Switching on the transmitter Once you have completed the post connection checks switch on the...

Страница 20: ...www addresses endress com 71486587 71486587...

Отзывы: