Fieldgate FXA720
6 Configuring the Web Server
Hauser
35
6.5
Network setup
The
"Network Setup"
function contains the parameters for setting up Ethernet, SMTP and other
network related parameters as well as addresses for e-mails and SMS messages (in preparation).
Procedure
1 If not already selected, press
"Switch to Specialist Mode"
and log in as administrator.
2 Press
"Information & Configuration",
then
"Network Setup"
.
The Network Setup screens appear:
6.5.1 Ethernet
1 The Ethernet screen allows you to configure the Ethernet connections of the Fieldgate.
2 Enter your settings and confirm with "
Send
".
Caution
• Each IP address may only occur once in a network! You can get an IP address from your
Internet provider or your system administrator.
• If you change the IP address in this screen:
– Close the connection (it may break off automatically)
– Use the new address in your browser to call up the Fieldgate.
– If appropriate, enter the new IP address in the PROFIBUS driver of any host application,
see Chapter 5.3.
Network parameters
Table 6-6: Ethernet network parameters
Parameter
Description
Fieldgate
Hostname
Enter a host name for the Fieldgate. This is a symbolic name (string) that can be more easily
memorized than an IP address.
IP Address
Enter the IP address of the Fieldgate here (factory setting is 192.168.253.1). You can get this
address from your system administrator.
Subnet Mask
Enter the IP address of the netmask.
Gateway
If appropriate, enter the address of the gateway connecting the LAN to the worldwide web via
firewall/router