Fieldgate FXA520
5 Commissioning
Hauser
43
5.3.2 Set up the Fieldgate via service interface
1 Press
Switch to Administration Mode
Now press
Settings
followed by
Network
– In the
Modem Setup dialog
enter the parameters as appropriate, see Table 5-2
(The screenshot above is an example for US specifications, with default settings for
IP addresses)
– Press
"Send"
to download the parameters to the Fieldgate
2 Now scroll down to the
Dial-up Setup
dialog
– Enter the parameters as appropriate, see Table 5-3
(The screenshot above is an example for callback to arcor, Berlin)
– Press
"Send"
to download the parameters to the Fieldgate
3 Now configure any other communication parameters, e.g. e-mails, as described in Chapter 5.5.
4 You may now wish to configure additional Fieldgate device functions, e.g. limit values,
scanning cycle, in the Fieldgate Web server as described in Chapter 6.
5 When configuration is complete, select
Settings => Special
to restart the system and register
the changes.
– In the
System Restart
dialog, check the "Confirm System Restart" box and press
Send
– The Fieldgate restarts with the changes made via the service interface permanently stored
6 When the restart is complete, close the web server, unplug the service connector and switch
off the Fieldgate. Close the front panel.
7 Plug in the telephone connector and switch on the Fieldgate. Connect the Fieldgate via the
host computer as described in Chapter 5.3.4.