![Endress+Hauser Ecograph T RSG30 Скачать руководство пользователя страница 13](http://html.mh-extra.com/html/endress-hauser/ecograph-t-rsg30/ecograph-t-rsg30_operating-instructions-manual_2408570013.webp)
Wiring
13
4.1.3
Auxiliary voltage output for 2-wire sensors
Fig. 6:
Using the auxiliary voltage output as power supply for 2-wire sensors (at current measurement range)
5
6
9
1
DI3
93
92
91
GND
RxD/TxD +
RxD/TxD -
Ethernet
RS232
Rel2
41
42
31
32
21
22
11
13
12
L+
N-
PE
Rel4 Rel3
Rel1
RS485
CH 4
CH 5
CH 6
61
1
612
613
614
615
616
41
1
412
413
414
415
416
CH 1
CH 2
CH 3
111
11
2
11
3
11
4
11
5
11
6
21
1
212
213
214
215
216
31
1
312
313
314
315
316
51
1
512
513
514
515
516
_
+
-
Y
+
-
Y
+
+
_
Out: max. 250 mA
On connecting channels 1-4 see
terminal connections CH 5-6
Sensor 1
e.g. TR10 from E+H
Sensor 2
External display
(optional) e.g.
RIA261 from E+H