Cerabar S/Deltabar S/Deltapilot S 4...20mA HART
Description of parameters
Hauser
93
CUST. UNIT FACT. P (317)
Entry
Enter conversion factor for a customer-specific pressure unit.
The conversion factor must be entered in relation to the SI unit "Pa".
See also
CUSTOMER UNIT P.
Prerequisite:
• PRESS. ENG. UNIT = User unit
Example:
– You want the measured value to be displayed in "PU" (PU: packing unit).
– MEASURED VALUE =10000 Pa
i
1 PU
– Entry CUSTOMER UNIT P: PU
– Entry CUST. UNIT FACT. P: 0.0001
– Result: MEASURED VALUE = 1 PU
Factory setting:
1.0
FLOW-MEAS. TYPE (640)
Selection
Select the flow type.
Options:
• Volume p. cond. (volume under operating conditions)
• Gas norm. cond. (norm volume under norm conditions in Europe: 1013.25 mbar and
273.15 K (0°C))
• Gas std. cond. (standard volume under standard conditions in USA: 1013.25 mbar
(14.7 psi) and 288.15 K (15°C/59°F))
• Mass (mass under operating conditions)
Factory setting:
Volume p. cond.
UNIT FLOW (391)
Selection
Select volume flow unit.
When a new flow unit is selected, all flow-specific parameters are converted and
displayed with the new unit within a flow mode (FLOW-MEAS. TYPE). When the flow
mode is changed, conversion is not possible.
Prerequisite:
• FLOW-MEAS. TYPE = Volume p. cond.
Options:
• m3/s, m3/min, m3/h, m3/day
• l/s, l/min, l/h
• hl/s, hl/min, hl/day
• ft3/s, ft3/min, ft3/h, ft3/day
• ACFS, ACFM, ACFH, ACFD
• ozf/s, ozf/min
• US Gal/s, US Gal/min, US Gal/h, US Gal/day
• Imp. Gal/s, Imp. Gal/min, Imp. Gal/h
• bbl/s, bbl/min, bbl/h, bbl/day
• User unit,
see also this table, parameter description for CUSTOMER UNIT F and
CUST. UNIT FACT. F
Factory setting:
m
3
/s
NORM FLOW UNIT (661)
Selection
Select norm volume flow unit.
When a new flow unit is selected, all flow-specific parameters are converted and
displayed with the new unit within a flow mode (FLOW-MEAS. TYPE). When the flow
mode is changed, conversion is not possible.
Prerequisite:
• FLOW-MEAS. TYPE = Gas norm conditions
Options:
• Nm3/s, Nm3/min, Nm3/h, Nm3/day
• User unit,
see also this table, parameter description for CUSTOMER UNIT F and
CUST. UNIT FACT. F
Factory setting:
Nm
3
/s
Table 14: (GROUP SELECTION
)
OPERATING MENU
SETTINGS
BASIC SETUP "Flow"
Parameter name
Description