Description of parameters
Cerabar S/Deltabar S/Deltapilot S 4...20mA HART
64
Hauser
OUTPUT UNIT (023)
Options
Select unit for measured value display and MEASURED VALUE parameter (
Page 122).
!
Note!
The selected unit is used only to describe the measured value. This means that when
selecting a new output unit, the measured value is not converted.
Example:
• current measured value: 0.3 ft
• new output unit: m
• new measured value: 0.3 m (9.8 ft)
Options:
• %
• mm, cm, dm, m
• ft, inch
• cm
3
, dm
3
, m
3
,m
3
E
3
• l, hl
• ft
3
, ft
3
E
3
• gal, bbl, Igal
• g, kg, t
• lb, ton, oz
Factory setting:
%
HEIGHT UNIT (003)
Options
Select height unit. The measured pressure is converted to the chosen height unit using
the DENSITY UNIT and ADJUST DENSITY parameters.
Options:
• mm
• cm
• dm
• m
• inch
• ft
Factory setting:
m
CALIBRATION MODE (008)
Options
Select calibration mode.
Options:
• Wet
Wet calibration takes place by filling and emptying the container. The measured
pressure is converted to the chosen height unit using the HEIGHT UNIT, DENSITY
UNIT and ADJUST DENSITY parameters. In the case of two different levels, the level,
volume, mass or percentage value entered is assigned to the converted height value.
• Dry
Dry calibration is a theoretical calibration. For this calibration, specify two height-level
value pairs via the EMPTY CALIB., EMPTY HEIGHT, FULL CALIB. and FULL
HEIGHT parameters.
Factory setting:
Dry
DENSITY UNIT (001)
Options
Select density unit. The measured pressure is converted to a height using the HEIGHT
UNIT, DENSITY UNIT and ADJUST DENSITY parameters.
Options:
• g/cm
3
• kg/dm
3
• kg/m
3
• US lb/in
3
• US lb/ft
3
Factory setting:
kg/dm
3
ADJUST DENSITY (007)
Entry
Enter density of fluid. The measured pressure is converted to a height using the HEIGHT
UNIT, DENSITY UNIT and ADJUST DENSITY parameters.
Factory setting:
1.0
Table 9: (GROUP SELECTION
) OPERATING MENU
SETTINGS
BASIC SETUP "Level",
LEVEL SELECTION "Level Easy Height"