Operation
Deltabar S FMD77, FMD78, PMD75 with FOUNDATION Fieldbus
50
Hauser
6.3.9
Methods
The FOUNDATION Fieldbus Specification includes the use of methods to make device
operation easier. A method is a sequence of interactive steps to be carried out in the specified
order so as to configure certain device functions.
The following methods are available for Deltabar S:
• Restart (Resource Block)
• Troubleshooting information, Config. Error No, Alarm Table (Diagnostic Block)
• Peakhold indicator, HistoROM (Service Block)
• Sensor Trim (TRD Block)
For further information on accessing methods, see the description of the FF configuration
program used.
TOTALIZER_1_UNIT
Total. 1 eng. unit
26
Unsigned16
2
S
x
x
OOS
7864
TOTALIZER_1_MODE
Neg. flow tot. 1
27
Unsigned8
1
S
x
x
OOS
7864, 333
TOTALIZER_1_FAIL_SAFE_MODE
Fail safe mode
28
Unsigned8
1
S
x
x
TOTALIZER_1_RESET
Reset totalizer 1
29
Unsigned8
1
D
x
x
OOS
CUSTOMER_UNIT_TOT_1
Tot. 1 user unit
30
Visible String 8
S
x
x
AUTO, OOS, MAN 7864
CUSTOMER_UNIT_FACTOR_TOT_1
Fact. u. u. total. 1
31
Float
4
S
x
x
OOS
7864
TOTALIZER_2_VALUE
Totalizer 2
32
Float
4
D
x
TOTALIZER_2_UNIT
Total. 2 eng. unit
33
Unsigned16
2
S
x
x
OOS
7864
TOTALIZER_2_MODE
Neg. flow tot. 2
34
Unsigned8
1
S
x
x
OOS
7864, 333
CUSTOMER_UNIT_TOT_2
Tot. 2 user text
35
Visible String 8
S
x
x
AUTO, OOS, MAN 7864
CUSTOMER_UNIT_FACTOR_TOT_2
Fact. u. u. total. 2
36
Float
4
S
x
x
OOS
7864
Parameter name,
option "Symbolic name"
Parameter name,
option "Label"
Index Data type
Size
(Byte)
Storage
Class
Read
Write BLK_MODE
Reset codes