Assembling and mounting the "separate housing" version
P01-xMD7xxxx-11-xx-xx-xx-011
Fig. 25:
"Separate housing" version
1
In the "separate housing" version, the sensor is supplied with the process connection and cable ready-fitted.
2
Cable with connection jack
4
Plug
5
Locking screw
6
Housing fitted with housing adapter, included
7
Mounting bracket suitable for wall and pipe mounting, included
Assembly and mounting
1. Insert the 10-pin connector (item 4) into the corresponding connection jack of the cable
(item 2).
2. Plug the cable into the housing adapter (item 6).
3. Tighten the locking screw (item 6).
4. Mount the housing on a wall or pipe using the mounting bracket (item 7).
When mounting on a pipe, tighten the nuts on the bracket uniformly with a torque of
at least 5 Nm (3.69 lbs ft).
Mount the cable with a bending radius (r)
120 mm (4.72 in).
r
³
120 mm
1