Proline Promag 50
ATEX II3G
0
Hauser
19
Description of measuring
system
The measuring system consists of transmitters and sensors.
Two versions are available:
• Compact version: transmitters and sensors form a mechanical unit.
• Remote version: transmitters and sensors are separated by open ground when installed and connected to
each other via a connecting cable.
Nameplates
The nameplates, which are mounted in a clearly visible position on the transmitter and sensor, contain all of
the relevant information about the measuring system.
A0005625
Fig. 1:
Example for nameplates of a transmitter and of a sensor
A
Transmitter nameplate
B
Sensor nameplate
1
Manufacturer / Certificate recipient
2
Transmitter or sensor type
3
Order code and serial number
4
Power supply, frequency and power consumption
5
Additional specifications, e.g. EPD = empty pipe detection, RB = reference electrode, etc. (only if present)
6
Available inputs/outputs
7
Space for additional information on special products
8
Year of manufacture
9
Identification of the type of protection, explosion group, temperature class, Ingress protection
10 Type of protection
11 Space for notes, e.g. delays, etc. (only if necessary)
12 Ambient temperature range
13 C-Tick symbol
14 Space for notified body for quality assurance monitoring
15 Equipment group and equipment category as per directive 94/9/EC
16 Associated Ex documentation
17 Space for other approval specifications and certificates, e.g. PROFIBUS, etc. (only if present)
18 Calibration factor/zero point
19 Nominal diameter/nominal pressure
20 Fluid temperature range
21 Lining material
22 Measuring electrode material
23 Calibration tolerance
24 Direction of flow
PROMAG 5X
PROMAG 5X
-20°C (-4°F) <Tamb<+60°C (+140°F)
-20°C (-4°F) <Tamb<+60°C (+140°F)
Pat. US 5,323,156 5,479,007
Pat. US 5,323,156 5,479,007
Pat. US 4,382,387 4,704,908 5,351,554
Pat. US 4,382,387 4,704,908 5,351,554
IP67 / NEMA/Type 4X
IP67 / NEMA/Type 4X
Order Code:
Order Code:
Ser.No.:
TAG No.:
TAG No.:
5XXXX-XXXXXXXXXXXX
12345678901
ABCDEFGHJKLMNPQRST
16-62VDC/20-55VAC
16-62VDC/20-55VAC
50-60Hz
50-60Hz
I-OUT (HART), f-OUT
I-OUT (HART), f-OUT
15VA/W
i
EPD/MSÜ
Pat. UK 2 084 740 EP 219 725 EP 521 169
Pat. UK 2 084 740 EP 219 725 EP 521 169
Pat. UK EP 541 878 EP 618 680
Pat. UK EP 541 878 EP 618 680
N12895
R/B
XA022D/06/a3/....
II3G
14
15
16
EEx nRC IIC T6 X
4153 Reinach Switzerland
2000
8
9
1
2
3
4
5
6
7
12
11
10
13
IP67 NEMA/Type4X
/
Pat. US 4,382,387 4,704,908 5,540,103
5XXXX-XXXXXXXXXXXX
0.5328/5
0.5328/5
PFA
-10°C...150°C/+14°F...300°F
-10°C...150°C/+14°F...300°F
12345678901 RY
12345678901 RY
ABCDEFGHJKLMNPQRST
DN100 DIN/EN PN40
DN100 DIN/EN PN40
EPD/MSÜ, R/B
EPD/MSÜ, R/B
Materials:
Order Code:
Order Code:
TM:
K-factor:
Ser.No.:
TAG No.:
TAG No.:
PROMAG P
PROMAG P
1.4435/316L
Electrode:
Electrode:
0.5CAL
N12895
XA022D/06/a3/....
II3GD
-20°C (-4°F)<Tamb<+60°C (+140°F)
2000
i
4153 Reinach
Switzerland
10
5
23
8
1
2
18
3
19
20
21
22
12
9
14
15
16
13
24
A
B
17
EEx nA II T6-T1 X
Содержание BA046D
Страница 41: ...Proline Promag 50 Endress Hauser 41...
Страница 42: ...Proline Promag 50 42 Endress Hauser...
Страница 43: ...Proline Promag 50 Endress Hauser 43...
Страница 44: ...www endress com worldwide XA104D 06 a3 07 10 71114916 FM SGML 6 0...