Potential equalization
• The transmitter (compact and remote version) is to be securely connected to the potential equalization
system using the screw terminal on the outside of the transmitter housing. Alternatively, the transmitter of
the compact version as of serial number 4Axxxxxx000 can be connected to the potential equalization
system via the pipeline if a ground connection via the pipeline according to regulations can be assured.
• When using the remote version, the connection housing of the sensor must be grounded via the external
screw terminal. Alternatively, the sensor can be integrated into the potential equalization via the pipeline
as long as the pipeline provides a ground connection conforming to regulations.
!
Note!
Further information about potential equalization, shielding and grounding can be found in the associated
Operating Instructions.
Cable entries
• For the connection compartment (Ex d version); power supply cable, circuit cable:
Choice of cable gland M20
1.5 or thread for cable entries ½" NPT or G ½".
Ensure that the Ex d cable glands/entries are secured against self-locking and the associated seals are
arranged directly on the housing.
• For connection compartment (Ex e version);
power supply cable, circuit cable: Choice of cable gland M20
1.5 or thread for cable
entries ½" NPT or G ½". The cables must be installed such that they are fixed in place. Adequate strain relief
must be ensured.
• For connection compartment, remote version connecting cable:
Choice of cable gland M20
1.5 or thread for cable entries ½" NPT or G ½".
#
Warning!
When using cable glands M20
1.5:
• Only approved
cable glands may be used (
22 "Installation instructions").
• The cable glands must be very leak-tight.
Cable specification
You can find information about the cable specification in the associated Operating Instructions.
Connection of remote
version connecting cable
A0011783
Fig. 5:
Connection of remote version connecting cable
a
Wall-mount housing: ATEX II2GD / Zone 1, Zone 21
b
Remote version, flanged version
Wire colors (colour code according to DIN 47100):
Terminal No.: 4/5 = gray; 6/7 = green; 8 = yellow; 9/10 = pink; 11/12 = white; 41/42 = brown
Terminal assignment and connection data
The connection of the remote version, between the sensor and the transmitter, has Ex i explosion protection.
"
Caution!
Only preterminated connecting cables supplied by Hauser may be used.
4
5
6
7
8
9
10
11 12
41 42
4
5
6
7
8
9
10
11 12
41 42
S1 S1 S2 S2 GND TM TM TT TT
+
+
+
+
+
+
+
+
S1 S1 S2 S2 GND TM TM TT TT
a
b
Pipe
Pipe
Содержание ATEX II1/2GD
Страница 20: ...0ATEX II2GD II1 2GD IECEx Zone 1 Zone 21 Zone 0 1 Proline Promass 80 20 Endress Hauser ...
Страница 21: ...Proline Promass 80 ATEX II2GD II1 2GD IECEx Zone 1 Zone 21 Zone 0 1 0 Endress Hauser 21 ...
Страница 49: ...Proline Promass 80 XA00097D Endress Hauser 49 ...
Страница 50: ...www endress com worldwide XA00097D 06 A3 14 12 71146622 FM SGML 9 0 ...