INSTRUCTION MANUAL 

For Model 7264D Piezoresistive Accelerometer 

IM7264D, Revision B 

 

 

The Model 7264D is a low mass, miniature piezoresistive accelerometer.  Because of its small size, certain 

precautions must be observed when handling and mounting the accelerometer to avoid damaging the 

unit. 

 

Materials Required 

 

All  materials  used  in  the  mounting  of  the  accelerometer  are  supplied  with  the  unit  in  the  shipping 

container.  These materials include: 

 

 

(1) Allen Wrench for 0 - 80 screws - Endevco P/N EHM35 

 

(2) Size 0 flat washers - Endevco P/N EHW196 

 

(2) 0 - 80 x 3/16 inch socket head cap screws - Endevco P/N EH828 

 

Special Precautions 

 

The following precautions should be observed when handling and mounting the accelerometer. 

 

 

CAUTION- Avoid dropping the accelerometer or striking the unit against hard surfaces.  Keep the 

protective sleeve that is supplied with the unit, on until the unit is installed. 

 

 

CAUTION- When mounting the unit, do not over torque the screws.  The specified mounting torque 

of 2.6 in-lbf (0.29 N-m) recommended, 3.0 in-lbf (0.34 N-m) maximum is easily achieved with the 

provided Allen wrench.  Excessive torque may result in damage to the unit.  Do not use snap type 

torque wrenches. 

 

Check-out 

 

Upon receipt of the accelerometer, it should be checked to insure proper operation.  Three simple tests 

can be conducted without removing the unit from its shipping container and protective sleeve. 

 

1.  Impedance test - Open the accelerometer shipping box and unwind a few inches of cable.  Leave the 

accelerometer in the container.  Read the input impedance (Red to Black) and output impedance 

(Green to White) with an ohmmeter.  Refer to the accelerometer Calibration Data Sheet to determine 

the proper value of impedance.  The measured impedance should be within ±25% of this calibrated 

value. 

 

2.  Insulation  Resistance-  If  the  input  and  output  impedance's  are  within  acceptable  limits,  use  a 

multimeter,  ohmmeter  or  megohmmeter  set  at  50  volts  maximum.    Measure  the  insulation 

resistance between: 

 

 

a.  all leads connected together and the cable shield 

 

b.  all leads connected together and the transducer case 

 

c.  cable shield and the transducer case 

 

 

All three readings should be 100 megohms minimum. 

 

 