EDM01-33v1 DAG_7.5G4_Card_User_Guide
©2008 Endace Technology Ltd. Confidential - Version 1 - November 2008
45
Dagclock Statistics reset
Statistics are reset to zero when the following occur:
•
Loading a DAG driver
•
Loading firmware
•
dagclock
with a
-x
option
•
dagclock
with a
set or
reset
command.
Example
To view the default
dagclock
configuration:
dagclock –d0
The following is the output from DAG card that has its clock reference connected. The clock
statistics have been reset since the card was last synchronized.
Note:
Values will differ for
each DAG card type.
muxin rs422
muxout none
status Synchronised Threshold 596ns Failures 0 Resyncs 0
error Freq -30ppb Phase -60ns Worst Freq 75ppb Worst Phase 104ns
crystal Actual 100000028Hz Synthesized 67108864Hz
input Total 3765 Bad 0 Singles Missed 5 Longest Sequence Missed 1
start Thu Apr 28 13:32:45 2007
host Thu Apr 28 14:35:35 2007
dag Thu Apr 28 14:35:35 2007
Note:
For a description of the
dagclock
output see
Dagclock output explained
(page ).