EDM01-33v1 DAG_7.5G4_Card_User_Guide
44
©2008 Endace Technology Ltd. Confidential - Version 1 - November 2008
Dagclock
The DUCK is very flexible and can be used with or without an external time reference. It can
accept synchronization from one of several input sources and also be made to drive its
synchronization output from one of several sources.
Synchronization settings are controlled by the
dagclock
utility.
Note:
You should only run
dagclock
after you have loaded the appropriate FPGA images.
If at any stage you reload the FPGA images you must rerun
dagclock
to restore the
configuration.
Note:
when you run
dagconfig -d0 default
the
dagclock
inputs and outputs are also
reset to defaults.
A description of each argument is shown below:
Option
Description
-d DEVICE
--device DEVICE
Use the DAG device referred to by DEVICE. Supported syntax includes 0,
dag1, and /dev/dag3 to refer to DAG cards.
-h, -?
--help, --usage
Display the information on this page
-k
--sync
Wait for DUCK synchronization before exiting
-K NUM
Set the synchronization timeout in seconds (default is 60 seconds)
-l NUM
Set the Health threshold in nanoseconds. (default is 596ns)
-v
Increase output verbosity
-V
Display version information
-x
--clearstats
Clear clock statistics
Command
Description
default
Set the
dagclock
input and output to RS422 in and none out.
none
Clears the input and output settings.
rs422in
Sets the
dagclock
input to RS422.
hostin
Sets the
dagclock
input to Host (unused)
overin
Sets the
dagclock
input to Internal input
auxin
Sets the
dagclock
input to Auxiliary input (unused)
rs422out
Sets the
dagclock
output to repeat the RS422 input signal
loop
Output the selected input
hostout
Sets the
dagclock
output to host (unused)
overout
Internal output (master card)
set
Sets the DAG card's clock to computer clock time and clears clock statistics.
The DAG card takes approximately 20 to 30 seconds to re-synchronize.
reset
Full clock reset. Load time from computer, set RS422in, none out. Clears
clock statistics. The DAG card takes approximately 20 to 30 seconds to re-
synchronize.
Note:
By default, all DAG cards listen for synchronization signals on their RS-422 port,
and do not output any signal to that port.
Содержание DAG 5.2X
Страница 1: ...DAG 7 5G4 Card User Guide EDM01 33...
Страница 12: ......
Страница 18: ......
Страница 64: ......
Страница 66: ......