background image

EDM01-07: DAG 3.7G Card User Guide 

 

Version 7: May 2006 

16 

©2005 

In-Line 

Forwarding 

The DAG 3.7G card can be used as an 'inline' device to receive, inspect, filter 

and forward packets between Port A and Port B. 
The following information describes the DAG 3.7G card inline forwarding 

process. 

 

 

Process 

Description 

 

Inline transmission. 

This operation can be performed at 100% line rate in 

both directions simultaneously.  A PCI-X 133MHz 

slot is required for full performance and the 

performance may be limited by the host PC CPU 

and memory performance. 

 

dagfwddemo

 

Program. 

The 

dagfwddemo

 program is provided as a 

demonstration of how this can be achieved. This 

program forwards packets bidirectionally, applying a 

user supplied BPF filter to each packet with the host 

CPU. Packets which match the filter are forwarded, 

while packets that do not match are dropped. 
This is intended as a demonstration of Inline 

Forwarding technology for use in Firewall or 

IDS/IPS applications. It is not suitable for use as a 

production Firewall. 

 

Modification of 

packets.

 

Modification of packets during inspection is also 

possible. The modifications should not change the 

length of the packet, and the user is responsible for 

re-computing checksums as needed. 

 

Содержание DAG 3.7G Series

Страница 1: ......

Страница 2: ...39 0540 Fax 64 7 839 0543 Americas Endace USA Ltd Suite 220 11495 Sunset Hill Road Reston Virginia 20190 United States of America Phone 1 703 382 0155 Fax 1 703 382 0155 Europe Middle East Africa Enda...

Страница 3: ...d Materials The product that this manual pertains to may include extra components and materials that are not essential to its basic operation but are necessary to ensure compliance to the product stan...

Страница 4: ...EDM01 07 DAG 3 7G Card User Guide Version 7 May 2006 2005...

Страница 5: ...ter 3 Configuring the Card 7 Introduction 7 Engaging Failsafe Relays 7 LEDs and Inputs 7 Configuration Utility 8 Default Configuration 8 Interface Statistics 10 Chapter 4 Capturing Data 13 Starting a...

Страница 6: ...1 07 DAG 3 7G Card User Guide Version 7 May 2006 ii 2005 Table of Contents cont Chapter 6 Data Formats 25 Overview 25 Generic Header 25 Type 2 Record 26 Chapter 7 Troubleshooting 27 Reporting Problems...

Страница 7: ...for your specific network requirements Running a data capture session Synchronising clock time Data formats You can also find additional information relating to functions and features of the DAG 3 7G...

Страница 8: ...Installation Guide EDM 04 02 Windows Software Installation Guide Other Systems For advice on using an operating system that is substantially different from either of those specified above please cont...

Страница 9: ...series card interfaces and fed through framers into the Xilinx FPGA This FPGA contains an Ethernet processor and the DUCK timestamp engine Because of close association of the components packets are ti...

Страница 10: ...e failsafe feature of the DAG 3 7GF there are some advantages to using a straight through cable rather than a cross over one The DAG card captures all packets received on each port similar to a NIC in...

Страница 11: ...M 04 02 Windows Software Installation Guide as appropriate which are included on the CD shipped with the DAG card Inserting the DAG Card To insert the DAG card in the PC follow the steps described bel...

Страница 12: ...ernet The standard specifies a maximum cable length of 100 metres for 10Base T 100 BaseTX and 1000Base T operation over unshielded twisted pair CAT5E or better cable By default DAG 3 7G card automatic...

Страница 13: ...ne forwarding applications to reconnect the two ports in case of power failure When the relays are in this state the ports are not connected to the physical layer devices on the card To use the card i...

Страница 14: ...second More details about the meaning of the various parameters options are supplied through the help page dagthree h as well as via the manual page Default Configuration Before configuring the card f...

Страница 15: ...ed out to the slen length Avoid large values of slen in fixed length mode as short packets arriving will produce large padded records wasting bandwidth and storage space rxsplit Send data from Port A...

Страница 16: ...rr Ethernet Symbol Error Count Interface Statistics cont Example The following example is for a card with no valid input dagthree d dag0 si Spd Lnk FD Neg JB MA RF Err Spd Lnk FD Neg JB MA RF Err 1000...

Страница 17: ...0 1 0 0 10 1 1 1 0 0 0 0 10 1 1 1 0 1 0 0 10 1 1 1 0 0 0 0 10 1 1 1 0 1 0 0 10 1 1 1 0 0 0 0 If the RF or JB bits are 1 s this indicates a problem with the network link This may or may not be related...

Страница 18: ...EDM01 07 DAG 3 7G Card User Guide Version 7 May 2006 12 2005...

Страница 19: ...view As the DAG 3 7T card captures packets from the network link it writes a record for each packet into a large buffer in the host PC s main memory Avoiding Packet Loss To avoid packet loss the user...

Страница 20: ...is usually sufficient however if you do need to increase the amount of reserved memory please contact Endace customer support at support endace com for more information The dsize option sets the amou...

Страница 21: ...mitting You can capture received traffic while transmitting Capture programs such as dagsnap dagconvert and dagbits can be used while dagflood is sending packets Configuring DAG card for transmission...

Страница 22: ...C CPU and memory performance dagfwddemo Program The dagfwddemo program is provided as a demonstration of how this can be achieved This program forwards packets bidirectionally applying a user supplied...

Страница 23: ...ween DAG cards and coordinated universal time UTC You can obtain an accurate time reference by connecting an external clock to the DAG card using the time synchronisation connector Alternatively you c...

Страница 24: ...is allows an ultimate resolution of 2 32 seconds or approximately 233 picoseconds The ERF timestamp allows you to find the difference between two timestamps using a single 64 bit subtraction You do no...

Страница 25: ...DAG device K timeout sync timeout in seconds default 60 l threshold health threshold in ns default 596 Option default RS422 in none out none None in none out rs422in RS422 input hostin Host input unu...

Страница 26: ...Failures 0 Resyncs 0 error Freq 30ppb Phase 15ns Worst Freq 2092838ppb Worst Phase 33473626ns crystal Actual 100000023Hz Synthesized 67108864Hz input Total 225 Bad 0 Singles Missed 1 Longest Sequence...

Страница 27: ...tus Synchronised Threshold 11921ns Failures 0 Resyncs 0 error Freq 1836ppb Phase 605ns Worst Freq 143377ppb Worst Phase 88424ns crystal Actual 49999347Hz Synthesized 16777216Hz input Total 87039 Bad 0...

Страница 28: ...u Apr 28 14 48 34 2005 dag No active input Free running Note The slave card configuration is not shown as the default configuration will work Synchronising with Host To prevent the DAG card clock time...

Страница 29: ...ried on circuit A and the serial packet is connected to the B circuit Pin Assignments The 4 pin RJ11 connector pin assignments are shown below 1 Channel A 2 Channel B 3 Channel B 4 Channel A Ethernet...

Страница 30: ...EDM01 07 DAG 3 7G Card User Guide Version 7 May 2006 24 2005...

Страница 31: ...and splitting to be performed arbitrarily on ERF record boundaries Generic Header All ERF records share some common fields Timestamps are in little endian Pentium native byte order All other fields a...

Страница 32: ...value of 0 indicates the record was received from the host In the XScale Tx hole a value of 1 tells the ERF Mux to direct packets to the line A value of 0 directs packets to the host rlen Record lengt...

Страница 33: ...number Host PC type and configuration Host PC operating system version DAG software version package in use Any compiler errors or warnings when building DAG driver or tools For Linux and FreeBSD mess...

Страница 34: ...EDM01 07 DAG 3 7G Card User Guide Version 7 May 2006 28 2005...