background image

 Counting inputs
 (INA, INB)

  3 channels  (5V to 30V pulses)

  40ms, 20ms, 10ms, 1ms, 0.5ms, 0.1ms, 50

 (selectable by programming)

m

s

* 72x72mm sized.
* 2x6 digits display.
* Easy to use by front panel keypad.
* On and Off times of the input pulses can be selected.  
* Sensor type can be selected as PNP or NPN.
* Sampling time can be adjusted between 0.2s and 16.0s.
* Selectable functional reset.
* Double set-points control is made by 2 relays outputs.
* Output can be energized while process value is greater or lower than the
  preset value. 
* Time delay can be included to the output operation.
* Output can be energized continuously or just for a time interval of 0.1
   to 999.9 seconds. 
* Decimal point can be adjusted between 1. and 5. digits. 
* Prescaler factor can be adjusted between 0.00001 and  999.999 for calibration.
* Display configuration can be adjusted.
* Parameter access protection on 3 levels.
* Easy connection by removable screw terminals. 
* CE marked according to European Norms.

  Minimum On and Off times 
  for pulses

ENDA ETS762 TACHO LINE/SPEED METER

Thank you for choosing ENDA ETS762 TACHOMETER. 

INPUTS

 Adjustable between 0.2s and 16.0s.

 Sampling time

 1/5

ETS762-E-0

5-R

Read this document carefully before using this device. The guarantee will be expired by 
damaging of  the device if you don't attend to the directions in the user manual. Also we don't 
accept any compensations for personal injury, material damage or capital disadvantages.  

ENVIRONMENTAL CONDITIONS

 Height

 Max. 2000m

 Ambient/storage temperature

 Max. relative humidity

0 ... +50

 

°C/-25 ... +70°C  (with no icing) 

Rated pollution degree

TECHNICAL SPECIFICATIONS 

80  up to 31

decreasing linearly  50  at 40

%

%

°C 

°C

According to EN 60529                Front panel :    IP65
                                                       Rear panel  :    IP20

 Do not use the device in locations subject to corrosive and flammable gases.

 Supply

 230V AC +10% -20%, 50/60Hz or 24V AC ±10%, 50/60Hz or optional 9-30V DC / 7-24V AC ±10% SMPS

 Power consumption

Max. 7VA
2.5mm² screw-terminal connections

 Wiring
 Date retention 
 EMC

 Safety requirements

 EN 61326-1: 1997, A1: 1998, A2: 2001 (Performance criterion B for the EMC standard)  

EEPROM (Min. 10 years)

 EN 61010-1: 2001 (pollution degree 2, overvoltage category II)

ELECTRICAL CHARACTERISTICS

 OUTPUTS

 Control output (OUT1)

 Relay : 250V AC, 2A (for resistive load), NO+NC

 Control output (OUT2)

 Open collector output (S.S. OUT1): Max. 30V DC, 100mA.  
 Relay : 250V AC, 2A (for resistive load), NO+NC

 Auxiliary power supply

 Open collector output (S.S. OUT2): Max. 30V DC, 100mA.
 12V DC, Max. 50mA (without regulation)

 

.

Mechanical  30.000.000 operation; Electrical 300.000 operation

  Life expectancy for relays

  

               Similarly, w

hen OUT2 relay is energized S.S. OUT2 transistor goes into saturation.

  Note : Relay and S.S.OUT outputs are in synchronization . When OUT1 relay is energized S.S. OUT1 transistor goes into saturation.

HOUSING

 Housing type

 Suitable for flush-panel mounting according to DIN 43 700.

 Dimensions

 W72xH72xD97mm 

 Weight

 Approx. 405g (after packing)

 Enclosure material

 Self extinguishing plastics 

 While cleaning the device, solvents (thinner, benzine, acid etc.) or 

corrosive materials 

must not be used.

 PNP: 5V to 30V pulse with adjustable  pulse time between 2ms and 50ms.
 NPN: GND terminal is connected to the RESET IN or HOLD IN terminal.

 RESET and HOLD inputs

Accuracy

±

0.1%

Order Code :

  

ETS762-     

1

     Supply Voltage

     230VAC...230V AC
     24VAC.....24V AC 
     SM...........9-30V DC / 7-24V AC 

ENDA

ETS762

SET

      PRESET TACHO/LINE SPEED METER

OUT1

OUT2

IN A

IN B

PRESET

RESET

Содержание ETS762

Страница 1: ...TIONS 80 up to 31 decreasing linearly 50 at 40 C C According to EN 60529 Front panel IP65 Rear panel IP20 Do not use the device in locations subject to corrosive and flammable gases Supply 230V AC 10 20 50 60Hz or 24V AC 10 50 60Hz or optional 9 30V DC 7 24V AC 10 SMPS Power consumption Max 7VA 2 5mm screw terminal connections Wiring Date retention EMC Safety requirements EN 61326 1 1997 A1 1998 A...

Страница 2: ...ameter selected by parameter during run mode 1 The value of the measurement selected by parameter during run mode Parameter name during programming mode ENDA ETS762 SET PRESET TACHO LINE SPEED METER OUT1 OUT2 IN A IN B PRESET RESET 12 11 184 253V AC 50 60Hz 7VA Switch Fuse F 100 mA 250V AC Neutral Line SUPPLY NOTE Fuse should be connected 230V AC Supply Cable size 1 5mm 1 Mains supply cords shall ...

Страница 3: ...eriod period time inter out1 lo out2 lo out1 Hi out2 Hi out1 Hi out2 lo out1 lo out2 Hi time inter PUls time PUls time Count per pls Count per Cyc dEci Point output config diSP CAL out1 PULs ti set dsp config prset1 prset2 User define out2 pUls t2 User define inP opt seCUr dSP oPt seCUr out oPt seCUr nonE Prog no Prog yES nonE Prog no Prog yES nonE Prog no Panel reset Prog yES reset input SEcur co...

Страница 4: ... Tb Tb Tb T2 Ta Td Td T3 Ta T2 T2 Td Td T3 T3 Ratio of the revolutions of IN A and IN B Speed measurement method Time difference measurement method Pulse duration measurement method Pulse counting method Pulse counting method Period measurement method second second second second second second second second second second second second second second second second second out1 Hi out2 Hi 999 999 Reset...

Страница 5: ...a com tr 5 5 ETS762 E 05 R NOTE NPN PROXIMITY SWITCH connection is the same as PNP PROXIMITY SWITCH connection PNP PROXIMITY SWITCH GND OUT 12V PNP PROXIMITY SWITCH PNP PROXIMITY SWITCH GND 12V 12V GND OUT OUT TYPICAL SENSOR CONNECTIONS TERMINAL CONNECTIONS 230V AC Supply Switch Cable size 1 5mm Fuse F 100 mA 250V AC 230V AC Supply Switch Cable size 1 5mm Fuse F 100 mA 250V AC ...

Отзывы: