TECHNICAL SPECIFICATIONS

Supply

230V AC +10

-20 , 50/60Hz or 24

%

%

V AC/DC 10%, 50/60Hz or 12V AC/DC 10%, 50/60Hz

±

±

Power consumption

Max 4VA
2.5mm² screw-terminal connections

±

1%

4 digits, 12.5mm, 7 segment yellow LED

Wiring
Scale
Sensitivity
Time Accuracy
Indicator
EMC

Safety requirements

EN 61326-1: 1997, A1: 1998, A2: 2001 (Performance criterion B is satisfied for EMC tests.
The device is designed to operate in controlled electromagnetic environment)
EN 61010-1: 2001 (

)

pollution degree 2, overvoltage category II

START INPUT

Input type

Control with mechanical contact.
Min. = 100ms, Max. =

On and Off times for input pulses

OUTPUT

ELEKTRÝKSEL ÖZELLÝKLER

OUT

Relay: 250V AC, 8A (

), NO+NC

for resistive load

Mechanical  30.000.000 operation; Electrical 100.000 operation

Life expectancy for relay

ENVIRONMENTAL CONDITIONS

Height

2000m

Max.

80% up to 31°C decreasing linearly  50% at 40°C.

Ambient/storage temperature
Max. Relative humidity

0 ... +50°C/-25 ... +70°C  (with no icing)

Selectable 99:59 min. or hour.
1 sec.

Rated pollution degree

According to EN 60529                Front panel :    IP6

Rear panel  :    Ip20

5

Do not use the device in locations subject to corrosive and flammable gases.

HOUSING

Housing type

Suitable for flush-panel mounting

Dimensions

W77xH35xD71mm

Weight

Approx. 198g (after packing)

Enclosure material

Self extinguishing plastics

Thank you for choosing ENDA ETM1411 digital timer.

* 35 x 77mm sized.

* Single contact output for timing control.

* External start input.

* Display can be adjusted to show min. or sec.

* Scale ;

0:01 .... 99:59 mins.

0:01 .... 99:59 hrs.

* Decrease and increace step of time can be adjusted.

* Start and stop possibility by front panel.

* 16 different warning tones.

* Upper and lower limits of the setpoint can be

adjusted.

* CE marked according to European Norms.

Connection Diagram

ENDA ETM 411 is intended for installation in control panels. Make sure that the device is
used only for intended purpose. The shielding must be grounded on the instrument side.
During an installation, all of the cables that are connected to the device must be free of
electrical power. The device must be protected against inadmissible humidity, vibrations,
severe soiling and make sure that the operation temperature is not exceeded. All input and
output lines that are not connected to the supply network must be laid out as shielded and
twisted cables. These cables should not be close to the power cables or components. The
installation and electrical connections must be carried out by a qualified staff and must be
according to the relevant locally applicable regulations.

1

Panel cut-out

Dimensions

Note: 1) Panel thickness

should be maximum
7 mm.

2) If there is no 60mm

free space at the back
side of the device, it
would be difficult to
remove it from the panel.

Holding screw
0.4-0.5Nm

Equipment is protected throughout
by DOUBLE INSULATION.

34mm

70mm

8mm

85mm

71mm

29mm

Flush mounting

clamp

Flush mounting

clamp

Depth

Rubber
gasket

Panel

For removing mounting clamps:

Push out the flush-mounting
clamp in direction

as shown

in the figure below. Then, pull
out the clamp in direction

1

2.

2

1

While cleaning the device, solvents (thinner, benzine, acid etc.) or

must not be used.

corrosive materials

SN: XXXXXXXXX

1

2

3

4

5

6

7

8

9

10

11

12

ETM1411-230V

AC

DIGITAL

TIMER

START

ENDA

INDUSTRIALELECTRONICS

230V

AC +10% -20%

50/60Hz   4V

A

OUT

250V

AC 8A

RESISTIVE LOAD

7
8

SUPPLY:

NOTE :

184-253V AC
50/60Hz 4VA

Line

Neutral

230V AC
Supply

Switch

Note:

Cable size: 1,5mm²

Fuse

F 100 mA

250V AC

Fuse should
be connected.

1)

2)

Mains supply cords shall meet the requirements of

IEC 60227 or IEC 60245.

In accordance with the safety regulations, the power

supply switch shall bring the identification of
the relevant instrument and it should be easily accessible
by the operator.

ENDA ETM1411 DIGITAL TIMER

SET

START

STOP

ETM1411

DIGITAL TIMER

ENDA

OUT

MIN

HOUR

4

Please read this document carefully before using this product. The guarantee will be
invalidated if the device is damaged by not following instructions detailed in the
manual. The company shall not be responsible for any damage or losses however
caused, which may be experienced as a result of the installation or use of this product.

Order Code : ETM1411-

1

Supply Voltage

230VAC...230V AC
24............24V AC/DC
12............12V AC/DC

SET

START

STOP

ETM1411

DIGITAL TIMER

ENDA

OUT

HOUR

MIN

SN: XXXXXXXXX

1

2

3

4

5

6

7

8

9 10 11 12

ETM1411-230VAC
DIGITAL TIMER

START

ENDA

INDUSTRIAL ELECTRONICS

230V

AC +10% -20%

50/60Hz   4V

A

OUT

250V

AC 8A

RESISTIVE LOAD

START

SN: XXXXXXXXX

1

2

3

4

5

6

7

8

9 10 11 12

ETM1411-24
DIGITAL TIMER

ENDA

INDUSTRIAL ELECTRONICS

24V

AC/DC ±10%

50/60Hz   4V

A

OUT

250V

AC 8A

RESISTIVE LOAD

SURAN

Industrieelektronik

D-72160 Horb a.N.

Dettinger Str. 9

Tel.: +49 (0)7451 / 625 617

E-mail : [email protected]

Fax: +49 (0)7451 / 625 0650

Internet : www.suran-elektronik.de

1./2

ETM1411-E

uptodate:01022014,modificationreservedandcanbechangeanytimepreviousnotice!