background image

ENDA ETI741 TEMPERATURE INDICATOR

TECHNICAL SPECIFICATIONS 

 ETI741-E-04-R

 1/3

* 72 x 72mm sized.
* 4 digits display.
* Selectable sensor type.
* Input offset feature.
* Parameter access protection on 3 levels.
* Programming just by using keypad.
* CE marked according to European Norms.
* Measurement at

 

°C and °F units.

Read this document carefully before using this device. The guarantee will be expired by 
damaging of  the device if you don't attend to the directions in the user manual. Also we don't 
accept any compensations for personal injury, material damage or capital disadvantages.  

Sensor type

 Temperature range

 J (Fe-CuNi) Thermocouple

 K (NiCr-Ni) Thermocouple

 T (Cu-CuNi) Thermocouple
 S (Pt10Rh-Pt) Thermocouple

 R (Pt13Rh-Pt) Thermocouple

               EN 60584
               EN 60584
               EN 60584
               EN 60584
               EN 60584

 0...  600
 0...1200
 0...  400
 0...1600

                  0...1600

°C

°C
°C
°C
°C

  Accuracy

 0,2% (of full scale)
 0,2% (

f

of  ull scale)

1 digit
1 digit

 0,2% (

f

)

of  ull scale

1 digit

 0,2% (

f

)

of  ull scale

1 digit

 0,2% (

f

)

of  ull scale

1 digit

 +32... +1112

 +32... +2192
 +32...   +752
 +32... +2912

                  +32... +2912

°F
°F
°F
°F

°F

 Pt 100 Resistance Thermometer
 Pt 100 Resistance Thermometer

EN 60751
EN 60751

 -200...600 

 -99.9...300.0

°C
°C

 0,2% (

f

)

of  ull scale

1 digit

 0,2% (

f

)

of  ull scale

1 digit

   -328... +1112 

  -99.9...+543.0

°F
°F

°C

°F

ELECTRICAL CHARACTERISTICS

 Supply

 230V AC +10  -20 , 50/60Hz or 24V AC ±10 , 50/60Hz or optional 9-30V 

/ 7-24V AC 

SMPS

%

%

%

DC 

±10% 

 Power consumption

Max. 7VA
2.5mm² screw-terminal connections

 Wiring
 Line resistance 
 Data retention
 EMC
 Safety requirements

 EN 61326-1: 1997, A1: 1998, A2: 2001 (Performance criterion B for standard EN 61000-4-3)   

EEPROM (minimum 10 years)

 EN 61010-1: 2001 (Pollution degree 2, overvoltage category II)

For thermocouple max.100ohm, for 3 wired Pt 100 max. 20ohm

HOUSING

 Housing type

 Suitable for flush-panel mounting according to DIN 43 700.

 Dimensions  

 W72xH72xD97mm 

 Weight 

 Approx. 395g (after packing)
 Self extinguishing plastics. 

 Enclosure material 

ENVIRONMENTAL CONDITIONS

 Height

 Max. 2000m

80  up to 31     decreasing linearly  50  at 40    . 

%

%

 Ambient/storage temperature
 Max. relative humidity

0 ... +50    /   

-25... +70

°C

°C

°C

°C

Rated pollution degree

According to EN 60529                Front panel :    IP65
                                                       Rear panel  :    IP20

 Do not use the device in locations subject to corrosive and flammable gases.

 While cleaning the device, solvents (thinner, benzine, acid etc.) or 

corrosive materials 

must not be used.