ENDA ET4430 Скачать руководство пользователя страница 1

               EN 60584

               EN 60584

              DIN 43710

               EN 60584

               EN 60584

               EN 60584

               EN 60584

               EN 60584
               EN 60584

EN 60751
EN 60751

°C

°F

 -199.9...600.0

-30.0....600.0°C

-30.0....600.0°C

-30.0...999.9°C

-30.0...400.0°C

 -200...600 

-30....600°C

-30....600°C

-30...1300°C

-30....400°C

-40...1700°C
-40...1700°C

°C

°C

 -22.0....999.9 °F

 -22.0....999.9 °F

 -22.0....999.9 °F

 -22.0....752.0 °F

  -199.9...999.9

 -22....2372 °F

 -22......752
 -40....3092

                  -40....3092

   -328....1112 

 -22....1112 °F

 -22....1112 °F

°F
°F
°F

°F

°F

ET4430-EN-01-201222

              DIN 43710

ENDA

TM

ENDA 

ET4430

 PID 

TEMPERATURE

 CONTROLLER

Thank you for choosing 

ENDA 

ET4430

 Temperature

 

C

ontroller

 Devices

.

Please read this document carefully before using this product. The guarantee will be invalidated if the device is damaged by not following instructions 
detailed in the manual. The company shall not be responsible for any damage or losses however caused, which may be experienced as a result of the 
installation or use of this product.

Input Type

Scale Range

 J (Fe-CuNi) 

   

Thermocouple

 L (Fe-CuNi) 

   

Thermocouple

 J (Fe-CuNi) 

   

Thermocouple

 L (Fe-CuNi) 

   

Thermocouple

 K (NiCr-Ni) 

    

Thermocouple

 K (NiCr-Ni) 

    

Thermocouple

 T (Cu-CuNi) 

   

Thermocouple

 T (Cu-CuNi) 

   

Thermocouple

 S (Pt10Rh-Pt) Thermocouple
 R (Pt13Rh-Pt) Thermocouple

 PT100 Resistance Thermometer
 PT100 Resistance Thermometer

 0,5% (for full scale)

 0,5% (for full scale)

 0,5% (for full scale)

 0,5% (for full scale)

 0,5% (for full scale)

 0,5% (for full scale)

1 digit

1 digit

1 digit

1 digit

1 digit

1 digit

 0,5% (for full scale)

 0,5% (for full scale)

1 digit

1 digit

 0,5% (for full scale)

1 digit

 0,5% (for full scale)

1 digit

 0,2% (

)

for full scale

1 digit

 0,2% (

)

for full scale

1 digit

Accuracy

ENVIRONMENTAL CONDITIONS

Height

Ambient/storage temperature
Max. Relative humidity
Rated pollution degree

ELECTRICAL CHARACTERISTICS

Supply
Power consumption
Wiring
Line resistance
Data retention

EMC
Safety requirements

OUTPUTS

A1 Output

Life expectancy for relay

C/A2 Output

SSR  Output

C

ONTROL

C

ontrol 

type

Control algorithm
A/D 

converter

Sampling time
Proportional band
Control period

 Hysteresis

Output power

HOUSING

Housing type

Dimensions

Weight
Enclosure material

 90-250V AC  50/60Hz, 

  or  10-30VDC / 8-24VAC 

±

%10 SMPS

24V AC ±%10  50/60Hz

Max. 5VA
Power screw-terminal connections: 2.5mm²', Signal screw-terminal connections: 1,5mm².

 EN 61326-1: 2013 (Performance criterion B satisfied for EN 61000-4-3 standard).

EEPROM (minimum 10 years)

Max.

 100

 O

hm

 EN 61010-1: 2010 (Pollution degree 2, overvoltage category II)

Suitable for flush-panel mounting according to DIN 43 700.

W48xH48xD87mm

Approx. 250g
Self extinguishing plastics

Single Setpoint and Alarm Control.

On-Off / P, PI, PD, PID selection.
14

 bit

.

Min. 1

00ms

.

Can be adjusted between 

%0

.0

 

and

 %100

.0 . If 

 Pb=%0

.0

 

, ON

-

OFF

 

c

ontrol 

is selected.

Can be adjusted between 

and 125secs.

Can be adjusted between 1 and 50°C/F.
Setpoint value ratio can be adjusted between %0 and %100 .

Relay : 250V AC, 10A (for resistive load), NO+NC (Control or Alarm2 Output selection).

Relay : 250V AC, 5A (for resistive load), NO (Alarm1 and Cooling Control Output selection).

Max.

 2000m

0 ... +50°C/-25 ... +70°C

According to EN 60529;        Front panel     :    IP6

5,

     Rear panel  :    IP20

Max. SSR Output ; 24V 20mA.

Relative humidity 80% for temperatures up to 31°C decreasing linearly to 50% relative humidity at 40°C.

Without load 30.000.000 switching; 250V AC, 

8

A  (resistive load) 300.000 switching.

KEEP AWAY device from exposed to corrosive, volatile and flammable gases or liquids and DO NOT USE the device in similar hazardous locations.

Avoid any liquid contact when the device is switched on.
DO NOT clean the device with solvent (thinner, gasoline, acid etc.) and / or abrasive cleaning agents.

Self tune for automatic PID calculation or
manually enter PID parameters if known.

Three different feature assignments for digital input.
Three different feature assignments for the function (F) key.
Soft-Start feature.
SSR or Relay Output Control selection.
A1 Relay output 

programmable

 as primary Alarm or PID Cooling Control output.

C/A2 Relay output can be used as secondary Alarm or Temperature Control output.
Heating/Cooling control selection.

Zero point input shift

.

In case of sensor failure, periodically, auto-periodically running or relay state can be selected.
RS485 Modbus RTU communication protocol feature (Specify at order).
CE marked according to European Norms.

48x48mm sized.

PT100 ,J, K, L, T, S, R sensor type selections.

Dual setpoint value selection.

Auto calculation for PID parameters (SELF TUNE).

Order Code : ET4430

1

2

1 - 

     230VAC...90 - 250V AC
     24VAC.....24V AC
     SM...........10-30V DC / 
                      8-24V AC

Supply Voltage

2

 - 

     

RS.....

... 

RS485 

     

Blank

....

 

Modbus (Optional)

Modbus Available

                   (Optional / Specify at order).

N/A

Please  see  ET4430  Modbus  Address 
Map and Connection Diagram Guide for 
Modbus feature.

TEMPERATURE CONTROLLER

ET4430

     

SSR

F

SİSEL MÜHENDİSLİK ELEKTRONİK SAN. VE TİC. A.Ş.

Şerifali Mah. 

 Y.Dudullu  34775

ÜMRANİYE/İSTANBUL-TURKEY
Tel : +90 216 499 46 64 Pbx.    Fax : +90 216 365 74 01
url : www.enda.com.tr

Barbaros Cad. No:18

 1/4

Содержание ET4430

Страница 1: ...ee 2 overvoltage category II Suitable for flush panel mounting according to DIN 43 700 W48xH48xD87mm Approx 250g Self extinguishing plastics Single Setpoint and Alarm Control On Off P PI PD PID select...

Страница 2: ...SSR OUT DIN TC PT100 RS 485 A B RS 485 COM 8 680407 724222 INDUSTRIAL ELECTRONICS ENDA SN XXXXXXXXX MADE IN TURKEY 1 2 3 4 5 6 7 8 9 10 OUT1 OUT2 AC 250V 10A RESISTIVE LOAD AC 250V 5A RESISTIVE LOAD...

Страница 3: ...larm A1 tp indE Deviation Alarm A1 tp dE Band Alarm A1 tp bAnd SV CONT output set value ASV Alarm output set value ASV min 300 ASV maks 300 ASV min beginning of scale ASV max end of scale ASV min 0 AS...

Страница 4: ...tp Alarm2 types Four alarm types can be selected indE Independent alarm dE Deviation alarm bAnd Band alarm bAn i Band with inhibition A2s t Status selection for Alarm2 Output If Hi is selected A2 outp...

Страница 5: ...g output maximum out percentage Offset value Function control parameter 23040d 5A00h self tune stops when this value is entered 23041d 5A01h self tune starts when this value is entered 23042d 5A02h re...

Страница 6: ...045d 002Dh 0047d 002Fh 0048d 0030h 0049d 0031h 0050d 0032h 0051d 0033h 0052d 0034h 0041d 0029h 0042d 002Ah H41 H43 H44 H45 H47 H46 H48 H49 H50 H51 H52 H40 H42 R W R W R W R W R W R W R W R W R W R W R...

Страница 7: ...the query is not an allowable action for the slave If a Poll Program Complete command was issued this code indicates that no program function preceded it The data address received in the query is not...

Отзывы: