Technical Specifications
CONTROL
Control type
Single-setpoint control
On-Off control
Control algorithm
Hysteresis
0.
5
°C
.
ENVIRONMENTAL CONDITIONS
Height
Max. 2000m
Ambient/storage temperature
Max. relative humidity
0 ... +50°C/-25 ... 70°C (with no icing)
Protection class
According to EN 60529
Rare panel : IP20
Thank you for choosing ENDA ET1413A temperature controller
Connection Diagram
1/
2
SÝSEL MÜHENDÝSLÝK ELEKTRONÝK SAN. VE TÝC. A.Þ.
Yukarý Dudullu Barbaros Cad. Kutup Sok. No:20 34775 - ÜMRANÝYE/ÝSTANBUL/TÜRKÝYE
Tel : +90 216 499 46 64 Pbx. Fax : +90 216 365 74 01
url : www.enda.com.tr
HOUSING
Housing type
Dimensions
W77xH3
5
xD7
1
mm
Weight
Approx.223g (After packing)
Enclosure material
ENDA ET1413A NTC FAN CONTROL THERMOSTAT
Order Code :
ET
1
4
1
3A-NTC-
1
Supply Voltage
230VAC...230V AC
24............24V AC/DC
12............12V AC/DC
* 35 x 77mm sized.
* 4 digits display.
* Decimal display feature.
* 3 contact outputs for the fan and air condition control.
* For air-condition,on-off cooling control.
* Fan and air-condition is done manually on the front
panel keys.
* CE marked according to European Norms.
Supply voltage
230V AC +%10 -%20, 50/60Hz or 24V AC/DC ±%10,
or
50/60Hz
12V AC/DC ±%10, 50/60Hz
Power consumption
Max. 4.5VA
2.5mm²screw-terminal connections
4 digits, 12.5mm, 7 segment yellow LED
Connection
Scale
Sensitivity/Accuracy
Indicator
EMC
ELECTRICAL CHARACTERISTICS
-50 ...
+
110
°
C
0.1°C /
±
1°C
Front panel : IP65
OUTPUTS
A/C (Air-condition output)
Fan 1
Life expectancy for relay
Relay: 250V AC, 8A (for resistive load), NO+NC; 1/2 HP 240V AC
(for inductive load
)
Cos
F
= 0.4
Without load 30.000.000 switching; 250V AC, 8A resistive load 100.000 switching.
Relay: 250V AC, 8A (for resistive load), NO; 1/2 HP 240V AC
(
for inductive load
)
Cos
F
= 0.4
Relay: 250V AC, 8A (for resistive load), NO; 1/2 HP 240V AC
(for inductive load)
Cos
F
= 0.4
Fan 2
Panel cut-out
Dimensions
71mm
2
9
m
m
Flush mounting
clamp
Flush mounting
clamp
1
3
5
m
m
77mm
SET
°C
SET
ET1413A
ENDA
ENDA
A/C
SET
°C
SET
ET1413A
A/C
N
T
C
S
E
N
S
O
R
10 11 12
SN: XXXXXXXXX
ET1413A-NTC-24
DIGITAL THERMOSTAT
ENDA
INDUSTRIAL ELECTRONICS
2
4
V
A
C
+
1
0
%
-
2
0
%
5
0
/6
0
H
z
4
.5
V
A
F
A
N
1
2
5
0
V
A
C
8
A
R
E
S
IS
T
IV
E
L
O
A
D
F
A
N
2
2
5
0
V
A
C
8
A
R
E
S
IS
T
IV
E
L
O
A
D
N
T
C
S
E
N
S
O
R
A
/C
2
5
0
V
A
C
8
A
R
E
S
IS
T
IV
E
L
O
A
D
1
2
3
4
5
6
7
8
9 10 11 12
SN: XXXXXXXXX
ET1413A-NTC-12
DIGITAL THERMOSTAT
ENDA
INDUSTRIAL ELECTRONICS
1
2
V
A
C
+
1
0
%
-
2
0
%
5
0
/6
0
H
z
4
.5
V
A
F
A
N
1
2
5
0
V
A
C
8
A
R
E
S
IS
T
IV
E
L
O
A
D
F
A
N
2
2
5
0
V
A
C
8
A
R
E
S
IS
T
IV
E
L
O
A
D
N
T
C
S
E
N
S
O
R
A
/C
2
5
0
V
A
C
8
A
R
E
S
IS
T
IV
E
L
O
A
D
1
2
3
4
5
6
7
8
9 10 11 12
SN
: X
XX
XX
XX
XX
ET
14
13
A-N
TC
-2
30
VA
C
DIG
IT
AL
T
HE
RM
OS
TA
T
EN
DA
IN
DU
ST
RIA
L E
LE
CT
RO
NIC
S
2
3
0
V
A
C
+
1
0
%
-2
0
%
5
0
/6
0
H
z
4
.5
V
A
F
A
N
1
2
5
0
V
A
C
8
A
R
E
S
IS
T
IV
E
L
O
A
D
F
A
N
2
2
5
0
V
A
C
8
A
R
E
S
IS
T
IV
E
L
O
A
D
N
T
C
S
E
N
S
O
R
A
/C
2
5
0
V
A
C
8
A
R
E
S
IS
T
IV
E
L
O
A
D
1
2
3
4
5
6
7
8
9
10
11
12
Please read this document carefully before using this product. The guarantee will be
invalidated if the device is damaged by not following instructions detailed in the
manual. The company shall not be responsible for any damage or losses however
caused, which may be experienced as a result of the installation or use of this product.
ENDA ET1413A is intended for installation in control panels. Make sure that the device is used
only for intended purpose. The electrical connections must be carried out by a qualified staff
and must be according to the relevant locally applicable regulations. During an installation, all of
the cables that are connected to the device must be free of electrical power. The device must be
protected against inadmissible humidity, vibrations, severe soiling and make sure that the
operation temperature is not exceeded. The cables should not be close to the power cables or
components.
Holding screw
0.4-0.5Nm.
Equipment is protected throughout
by DOUBLE INSULATION
Neutral
230V AC
Supply
Switch
Note:
Cable size: 1,5mm²
Fuse
F 100 mA
250V AC
Fuse should
be connected
1) Mains supply cords shall meet the requirements of
IEC 60227 or IEC 60245.
2) In accordance with the safety regulations, the power
supply switch shall bring the identification of the
relevant instrument and it should be easily
accessible by the operator.
80%, up to 31°C decreasing linearly 50% at 40°C
Do not use the device in locations subject to corrosive and flammable gasses.
Safety requirements
The device is designed to operate in controlled electromagnetic environment)
EN 61326-1: 1997, A1: 1998, A2: 2001 (Performance criterion B is satisfied for EMC tests.
EN 61010-1: 2001 (Pollution degree 2, overvoltage category II)
Suitable for flush-panel mounting.
Self extinguishing plastics
While cleaning the device, solvents (thinner, benzine, acid etc.) or
corrosive materials
must not be used.
For removing mounting clamps:
Push the flush-mounting
clamp in
direction
1
as
shown
in the figure below. Then, pull
out the clamp in direction
2.
Note:
E
T1
4
1
3A-E-01
Depth
Panel
2
71mm
5mm
SN: XXXXXXXXX
ET1413A-NTC-230VAC
DIGITAL THERMOSTAT
ENDA
INDUSTRIAL ELECTRONICS
2
3
0
V
A
C
+
1
0
%
-
2
0
%
5
0
/6
0
H
z
4
.5
V
A
F
A
N
1
2
5
0
V
A
C
8
A
R
E
S
IS
T
IV
E
L
O
A
D
F
A
N
2
2
5
0
V
A
C
8
A
R
E
S
IS
T
IV
E
L
O
A
D
A
/C
2
5
0
V
A
C
8
A
R
E
S
IS
T
IV
E
L
O
A
D
1
2
3
4
5
6
7
8
9
7
8
SUPPLY:
NOTE:
184-253V AC
50/60Hz 4,5VA
Line
1) Panel thickness
should be maximum
7 mm.
2)
If there is no 60mm
free space at the back
side of the device, it
would be difficult to
remove it from the
panel.