For
utrr
0...9999V, for
u100
0........100V, for
u500
0...500V
0,1V (
If,
u500
is selected and
higher than
-100V, lower from 100V for input values
)
1V
(
If
u500
is selected and
lower than
-100V
, higher from
100V
for input values
)
0,01V ( If,
u100
or
utrr
is selected )
For
utrr
-999...9999V DC, for
u100
-100...100V DC, for
u500
-500...+500V DC
EPV742-E-01-170330
7
2
x
72
mm
sized
4
digits display
Selectable number of decimal point
Can be displayed between -999 and + 9999V by using voltage transformer
Easy to use front panel keypad
Multi-function alarm output for lower and upper limits (NO + NC)
Multi-function alarm setpoints with alarm output (NO)
Communication feature over isolated RS485, using ModBus RTU protocol (Optional)
Keylock feature
Measuring type can be selected as AC, DC or true RMS (ACDC)
CE Marked according to Europan Norms.
Order Code : EPV742 - - -
1
2
3
1 -
R..........Relay
Blank....N/A
Output
3
-
Isolated ModBus
(
Specify at Order
)
.
RS
I
......
Isolated
ModBus
2 -
230VAC...230V AC
110VAC...110V AC
24VAC.....24V AC
SM...........9-30V DC / 7-24V AC
Supply Voltage
OUTPUTS
Alarm Output
Relay: 250V AC, 8A (for resistive load), NO+NC
Life Expectancy for Relay
230V AC +10 -20 or 24V AC %10, 50/60Hz or 9-30V DC / 7-24V AC 10
%
%
% (Optional)
±
±
EN 61326-1: 2013
EN 61010-1: 2010 (Pollution degree 2, overvoltage category II)
Max. 5VA
AC
RMS
DC
(
)
Full scale
DC , 10Hz - 200Hz (For square wave form 10Hz-70Hz)
AC and RMS
DC
%1
±
%1
±
%1
±
-500V...500V
(
If
u500
is selected, device breaks down at more than ±1250 DC voltages.)
-
10
0V...
10
0V
(If
utrr
or
u100
is selected, device breaks down at more than ±250 DC voltages. )
870kΩ
1/4
SİSEL MÜHENDİSLİK ELEKTRONİK SAN. VE TİC. A.Ş.
Şerifali Mah.
Y.Dudullu 34775
ÜMRANİYE/İSTANBUL-TURKEY
Tel : +90 216 499 46 64 Pbx. Fax : +90 216 365 74 01
url : www.enda.com.tr
Barbaros Cad. No:18
ENDA
TM
Read this document carefully before using this device. The guarantee will be expired by
device damages if you don't attend to the directions in the user manual. Also we don't
accept any compensations for personal injury, material damage or capital disadvantages.
ENDA EPV
7
42 PROGRAMMABLE AC/DC VOLTMETER
Thank you for choosing
ENDA EPV
7
4
2
Programmable
AC/DC voltmeter.
Max.
2000m
0 ... +50°C/-25 ... +70°C (with no icing)
According to EN 60529
; Front Panel : IP6
5,
Rear Panel : IP20
80% Relative humidity for temperatures up to 31°C, decreasing linearly to 50% at 40°C.
Technical Specifications
Height
Ambient
/
S
torage
T
emperature
Max.
R
elative
H
umidity
Rated
P
ollution
D
egree
ENVIRONMENTAL CONDITIONS
Do not use the device in locations subject to corrosive and flammable gases.
ELECTRICAL CHARACTERISTICS
Supply
Voltage
Power
C
onsumption
Wiring
Scale
Sensitivity
Accuracy
EMC
Safety
R
equirements
Input Impedance
Frequency Range
Input Range
2.5mm² screw-terminal connections
( Full scale ) (
For square wave form 2%
)
±
(
Full scale
) (
For square wave form 2%
)
±
Mechanical 30.000.000 operation; 100.000 operation at 250V AC, 2A resistive load.
HOUSING
Housing
T
ype
Dimensions
Weight
Enclosure
M
aterial
Suitable for flush-panel mounting. (According to DIN 43 700)
W7
2
xH
72
xD
97
mm
Approx. 50g (after packing)
3
Self extinguishing plastics.
While cleaning the device, solvents (thinner, gasoline, acid etc.) or
corrosive materials
must not be used.
PROGRAMMABLE VOLTMETER
ENDA
EPV742
SET
LOCK
0.000
OUT
AC
DC
AC
/
DC