background image

OUTPUTS

 

Alarm output

 

 

Relay: 250V AC, 8A (for resistive load), NO+NC

 

Mechanical 30.000.000 ; Electrical 100.000 operation.

  

Life expectancy for relay

0 ... +50°C/-25 ... 70°C

HOUSING

 

Housing type

 

Suitable for flush-panel mounting.

 

(According to DIN 43 700)

 

Dimensions

  

 

 

W

77

xH

35

xD7

1

mm

 Weight 

 Enclosure material

 

Self extinguishing plastics.

ENDA

 

EPV

2

41

A

 AC/DC VOLTMETER 

 

While cleaning the device, solvents (thinner, benzine, acid etc.) or 

corrosive materials 

must not be used.

  

       

        

Approx.  350g (after packing)

 

 

SİSEL MÜHENDİSLİK ELEKTRONİK SAN. VE TİC. A.Ş.
Yukarı Dudullu Barbaros Cad. Kutup Sok. No:20 34775 - ÜMRANİYE/İSTANBUL/TÜRKİYE
Tel : +90 216 499 46 64 Pbx.    Fax : +90 216 365 74 01
url : www.enda.com.tr

* 77 x 3

5

mm sized.

* 3 digits display.

* Easy to 

configure with

 front panel keypad.

* Multifunctional alarm output (NO+NC) for upper and lower  

  limits.

 

Communication feature over isolated RS485, using ModBus 

RTU 

protocol. (Functional).

* Measuring type can be selected as AC, DC or true RMS.              
* CE marked according to Europan Norms.

Values between -100V and 100 V can be indicated with one 

   decimal point.

 

For maximum 50V AC/DC measurements, measurements

  between -50V and +50V can be shown with two decimal digits 
  by having 10 times more accurate measurement input.                

 

 

 

Supply

 230V AC +10% -20%, 50/60Hz  or  24V AC   10% , 50/60Hz  or  optional 9-30V DC / 7-24V AC  10% SMPS

±

±

 

Power consumption

2.5mm² screw-terminal connections

 

Wiring

 

Scale

 

Sensitivity

ELECTRICAL CHARACTERISTICS

      

If  

C.InP

500

 is selected, it is   

0V...500V

                   or If  

C.ınP ;50

 is selected, it is 0....50V

       If 

C.InP

 ;

500

 is selected,  it is  -500V DC....500V DC or If 

C.InP

;

50

 is selected, it is -50V DC....50V DC  

  

0,

01V  (If 

C.InP

;50

      is selected )

Max. 5VA

AC and RMS

:

DC

                :

EPV

2

41

A

-E-0

2-R-201307

1/

5

   

± 

 

Accuracy

 

EMC

 

 

Safety requirements

  

EN 61326-1

: 2006

 

 

EN 61010-1: 20

10

 (Pollution degree 2, overvoltage category II)

1%

  

AC

  

RMS

  

DC

   

± 

1%

1%

(Full scale)    (For square wave form  2%)

± 

(Full scale)

 

Input Impedance

  

870k

Ω

    

 

Frequency Range

 

Input Range

  -500V...500V (

If 

CINP 500

 is selected, device breaks down at more than 

±

1250 DC voltages.)

   

-50V

....50V      (If

 CInp

 

50   

 

is selected, device breaks down at more than 

±

125   DC voltages.)

   

± 

(Full scale)    (For square wave form  2%)

                                
   

± 

DC ,  10Hz - 200Hz    (For square wave form 10Hz-70Hz)

Thank you for choosing ENDA EPV

2

41

A

  AC/DC voltmeter. 

Read this document carefully before using this device. The guarantee will be expired by 
device damages  if you don't attend to the directions in the user manual. Also we don't  
accept any compensations for personal injury, material damage or capital disadvantages. 

Technical Specifications

 

.

Do not use the device in locations subject to corrosive and flammable gases

ENVIRONMENTAL CONDITIONS

 

Ambient/stroge temperature

 

Max. Relative humidity

Rated pollution degree

 

Height

80%  Relative humidity for temperatures up to 31 % °C,decreasing linearly  to 50% at 40°C.

According to EN 60529        Front panel   : IP6

5

    ,     Rear panel   : 

IP20

                                              

 

Max. 2000m

  

  

0,1V

   (If 

CINP;500

 

is selected and  higher than -100V or lower than 100V for input values)

    

   

1V  

  

(

If 

CINP

;

500  

is selected and lower than -100V or higher  than 100V for input values

)

        

 

                                       1-Output

     

                                            

R

......Relay

     

                                            None...No relay

   

                                         2

-

Supply Voltage

     

                                       

230VAC...230V AC

                  RSI..... Insulated ModBus (optional)                           

     

                                       110VAC...110V AC  

                                             

24VAC.....24V AC 

     

                                        

SM...........9-30V DC / 7-24V AC 

 

                   3-ModBus

SET

SET

 EPV 241A

ENDA

OUT         AC         DC         ACDC

V

Order Code  : EPV241A-    -             -     

2

3

  1

Содержание EPV241A

Страница 1: ...selected it is 500V DC 500V DC or If C InP 50 is selected it is 50V DC 50V DC 0 01V If C InP 50 is selected Max 5VA AC and RMS DC EPV241A E 02 R 201307 1 5 Accuracy EMC Safety requirements EN 61326 1...

Страница 2: ...temperature is not exceeded The cables should not be close to the power cables or components 35mm 77mm SET SET EPV 241A ENDA OUT AC DC ACDC V CAT II 1 2 3 4 5 6 7 8 9 10 ENDA INDUSTRIAL ELECTRONICS SN...

Страница 3: ...ue appears SET If key is pressed it returns to parameter name Hysteresis value for upper limit SET By using and keys hysteresis value for upper limit can be adjusted between 0 0V and 20 0V This parame...

Страница 4: ...00 9600 19200 SET If key is pressed it returns to parameter name There are only The AdrS and baud parameters are only in the devices those have modbus tYPE optn CInp parameters in the devices those ha...

Страница 5: ...Name 00d 0x00 Bit Relay output state 0 OFF 1 ON 1 3 DISCRETE INPUTS Coil Addresses Decimal Hex Data Type Data Content Parameter Name Read Write Permission 00d 0x00 Bit Alarm output state 0 no 1 nc Ao...

Страница 6: ...e category II 1 AC RMS DC 1 1 Full scale For square wave form 2 Full scale Input Impedance 870k Frequency Range Input Range 500V 500V If CINP 500 is selected device breaks down at more than 1250 DC vo...

Страница 7: ...or If C Inp input type 500 is selected the measurement terminals 1 and 4 of the terminals must be connected Otherwise the measurement will be incorrect If C np input type 50 is selected the measuremen...

Страница 8: ...sed it returns to parameter name Hysteresis value for upper limit By using and keys hysteresis value for upper limit can be adjusted between 0 0V and 20 0V This parameter can t be higher than value Up...

Страница 9: ...point The lower limit of the hysteresis value Delay time for the lower limit alarm Measurement method 0 AC 1 DC 2 ACDC Device address for RS485 network connection Adjustable between 1 247 Baudrate 0 O...

Страница 10: ...ivity ELECTRICAL CHARACTERISTICS If C InP 500 is selected it is 0V 500V or If C nP 50 is selected it is 0 50V If C InP 500 is selected it is 500V DC 500V DC or If C InP 50 is selected it is 50V DC 50V...

Страница 11: ...e according to the relevant locally applicable regulations During an installation all of the cables that are connected to the device must be free of electrical power The device must be protected again...

Страница 12: ...be lower than value lo l1 HYS l HYS U If this key is pressed upper limit value appears SET If key is pressed it returns to parameter name Hysteresis value for upper limit SET By using and keys hyster...

Страница 13: ...is pressed measurement input type s seen There are only The AdrS and baud parameters are only in the devices those have modbus c t r r tYPE d Pnt optn parameters in the devices those have no relay If...

Страница 14: ...ork connection Adjustable between 1 247 Baudrate 0 Off 1 1200 2 2400 3 4800 4 9600 5 19200 Readable Writable ENDA EPV741A DIGITAL VOLTMETER MODBUS PROTOCOL ADDRESS MAP Input Register Addresses Read Wr...

Отзывы: