SÝSEL MÜHENDÝSLÝK ELEKTRONÝK SAN. VE TÝC. A.Þ.
Yukarý Dudullu Barbaros Cad. Kutup Sok. No:20 34775 - ÜMRANÝYE/ÝSTANBUL/TÜRKÝYE
Tel : +90 216 499 46 64 Pbx. Fax : +90 216 365 74 01
url : www.enda.com.tr
EPA141-E-0
7-R
1/3
Technical Specifications
OUTPUTS
Alarm output
Relay: 250V AC, 8A (for resistive load), NO+NC
Mechanical 30.000.000 ; Electrical 100.000 operation.
Life expectancy for relay
ENVIRONMENTAL CONDITIONS
Height
Max. 2000m
80 up to 31
%
°C decreasing linearly 50% at 40°C.
Ambient/stroge temperature
Max. Relative humidity
0 ... +50°C/-25 ... 70°C
Rated pollution degree
According to EN 60529 Front panel : IP6
5
, Rear
panel : IP20
Do not use the device in locations subject to corrosive and flammable gases.
ENDA
EPA141 PROGRAMMABLE AC/DC AMMETER
Thank you for choosing ENDA EPA141 programmable AC/DC ammeter.
Read this document carefully before using this device. The guarantee will be expired by
damaging of the device if you don't attend to the directions in the user manual. Also we don't
accept any compensations for personal injury, material damage or capital disadvantages.
* 3
5
x 77mm sized.
* 4 digits display.
* Easy to use by front panel keypad.
* With current trafo or shunt can be used.
* Programmable scale between 5A and 9999A.
* Multifunctional alarm output (NO+NC) for upper and lower
limits.
* CE marked according to Europan Norms.
* Measuring type can be selected AC, DC or True RMS
Supply
230V AC +10% -20%, 50/60Hz or 24V AC 10% , 50/60Hz or optional 9-30V DC / 7-24V AC 10% SMPS
±
±
Power consumption
1.5mm² screw-terminal connections
Wiring
Scale
Sensitivity
Accuracy
EMC
Safety requirements
EN 61326-1: 1997, A1: 1998, A2: 2001 (Performance criterion B for the EMC standard)
EN 61010-1: 2001 (Pollution degree 2, overvoltage category II)
ELECTRICAL CHARACTERISTICS
0A...9999A (Specified
)
c.tr.r
c.tr.r
parameter. For example:scale is 0A...5A for
=5.00
0.002A x
( For example , 0.01A for
=5.00 )
c.tr.r
c.tr.r
Max. 5VA
AC
RMS
DC
±
1%
1%
(full scale) (For square wave form 2%)
±
(full scale)
(full scale) (For square wave form 2%)
±
Input impedance
EPA141Sxx 1
2m
Ù
EPA141xx 40k
Ù
Frequency Range
DC , 10Hz - 200Hz (For square wave form 10Hz-70Hz)
Input Range
EPA141Sxx -5A...5A (Device is damaged 10A peak and more current.)
EPA141xx -60mV...60mV
(Device is damaged 50V peak and more voltage.)
AC and RMS
DC
-999A...9999A (Specified
parameter. For example:scale is -5A...5A for
=5.00)
c.tr.r
c.tr.r
±
±
1%
HOUSING
Housing type
Suitable for flush-panel mounting.
Dimensions
W77xH3
5
xD7
1
mm
Weight
Enclosure material
Self extinguishing plastics.
EPA141 Approx. 250g (after packing)
EPA141-24 Approx. 250g (after packing)
While cleaning the device, solvents (thinner, benzine, acid etc.) or
corrosive materials
must not be used.
Order Code :
EPA141 - -
1 - Input Type
S.........Internal Shunt Resistor
None...External Shunt Resistor
3 - Supply Voltage
230VAC...230V AC
24VAC.....24V AC
SM...........9-30V DC / 7-24V AC
2 - Output
R.........Relay
None...No Relay
1 2 3
SET
SET
EPA 141
ENDA
OUT AC DC ACDC
A