background image

SÝSEL MÜHENDÝSLÝK ELEKTRONÝK SAN. VE TÝC. A.Þ.
Yukarý Dudullu Barbaros Cad. Kutup Sok. No:20 34775 - ÜMRANÝYE/ÝSTANBUL/TÜRKÝYE
Tel : +90 216 499 46 64 Pbx.    Fax : +90 216 365 74 01
url : www.enda.com.tr

EPA141-E-0

7-R

1/3

Technical Specifications

OUTPUTS

 

Alarm output

 

Relay: 250V AC, 8A (for resistive load), NO+NC 

 

Mechanical 30.000.000 ; Electrical 100.000 operation.

  

Life expectancy for relay

 

ENVIRONMENTAL CONDITIONS

 

Height

 Max. 2000m

80  up to 31

%

°C decreasing linearly  50% at 40°C.

 

Ambient/stroge temperature

 

Max. Relative humidity

0 ... +50°C/-25 ... 70°C

Rated pollution degree

According to EN 60529        Front panel   : IP6

5

    ,     Rear

                                              

 panel   : IP20

 Do not use the device in locations subject to corrosive and flammable gases.

ENDA

 

EPA141 PROGRAMMABLE  AC/DC AMMETER 

Thank you for choosing ENDA EPA141 programmable  AC/DC ammeter. 

Read this document carefully before using this device. The guarantee will be expired by 
damaging of  the device if you don't attend to the directions in the user manual. Also we don't  
accept any compensations for personal injury, material damage or capital disadvantages. 

* 3

5

 x 77mm sized.

* 4 digits display.
* Easy to use by front panel keypad.
* With current trafo or shunt can be used.
* Programmable scale between 5A and 9999A.
* Multifunctional alarm output (NO+NC) for upper and lower 
limits.
* CE marked according to Europan Norms. 
* Measuring type can be selected  AC, DC or True RMS   

 

Supply

 230V AC +10% -20%, 50/60Hz  or  24V AC   10% , 50/60Hz  or  optional 9-30V DC / 7-24V AC  10% SMPS

±

±

 

Power consumption

1.5mm² screw-terminal connections

 

Wiring

 

Scale

 

Sensitivity

 Accuracy

 

EMC

 

Safety requirements

 

 

EN 61326-1: 1997, A1: 1998, A2: 2001 (Performance criterion B for the EMC standard)

 

EN 61010-1: 2001 (Pollution degree 2, overvoltage category II)

ELECTRICAL CHARACTERISTICS

      

0A...9999A  (Specified 

)

c.tr.r

c.tr.r

 parameter. For example:scale is  0A...5A  for 

=5.00

 

 0.002A x 

      ( For example , 0.01A  for 

=5.00  )

c.tr.r

c.tr.r

Max. 5VA

  

AC

  

RMS

  

DC

   

±

 

1%
1%

(full scale)    (For square wave form  2%)

± 

(full scale)
(full scale)    (For square wave form  2%)

± 

 

Input impedance

  

EPA141Sxx     1

2m

Ù

 

   

  

EPA141xx        40k

Ù

    

 

Frequency Range

 

DC ,  10Hz - 200Hz    (For square wave form 10Hz-70Hz)

 

Input Range

  

EPA141Sxx     -5A...5A            (Device is damaged 10A peak and more current.)

 

 EPA141xx       -60mV...60mV

  

 (Device is damaged 50V peak and more voltage.)

AC and RMS
DC

 -999A...9999A  (Specified 

 parameter. For example:scale is -5A...5A  for 

=5.00) 

c.tr.r

c.tr.r

   

±

 

   

±

 

1%

HOUSING

 

Housing type

 

Suitable for flush-panel mounting.

 

Dimensions

  

 

W77xH3

5

xD7

1

mm

 

 

Weight

 

 

Enclosure material

 

Self extinguishing plastics.

 

EPA141           Approx.  250g (after packing)

 

 

EPA141-24      Approx.  250g (after packing)

 

While cleaning the device, solvents (thinner, benzine, acid etc.) or 

corrosive materials 

must not be used.

Order Code :

  

EPA141 - -     

1 - Input Type

     S.........Internal Shunt Resistor
     None...External Shunt Resistor

3 - Supply Voltage

     230VAC...230V AC
     24VAC.....24V AC 
     SM...........9-30V DC / 7-24V AC 

2 - Output

     R.........Relay
     None...No Relay

1   2          3

SET

SET

 EPA 141

ENDA

OUT         AC         DC         ACDC

A

Отзывы: