background image

encor

e n

!

etworks

TM

SignalPath

 201-SA

(SP201-SA

)

Installation Guide

Version C, July 2004

Part Number 15469.0100

SignalPath Software Version 1100

This 

Installation Guide

 presents a quick, standard installation of the SP201-SA. 

Note:  

The needs of your network may require an installation that varies from the standard installation. 

For a customized installation, see the 

SP201-SA Customization and Maintenance Guide

. For hardware 

information, see the 

SP201-SA Hardware Reference Guide

The SP201-SA is available in two versions: 

• The two-port SP201-SA, supporting one trunk circuit of up to 30 channel circuits 

• The four-port SP201-SA, supporting up to two trunk circuits of up to 30 channel circuits each (for a total 

of up to 60 channel circuits) 

Note:  

A standard trunk circuit (from one external device, through the SP201-SA, to another external 

device) comprises trunk connections to two ports. The SignalPath™ configuration software defines each 
side of the trunk circuit (that is, each connection to a port) as a trunk. 

This document uses the term 

trunk

 to indicate a connection to one port; it uses the term 

trunk circuit

 to 

indicate the complete end-to-end connection (over two ports). Using these definitions, a trunk circuit 
comprises two trunks. 

Before you start this installation, be sure you have filled out the worksheet for adding this device to your 
network. See the 

SP201-SA Site Planning Worksheet

See the following sections for a standard installation of the SP201-SA: 

Section A, 

Physical Installation

 

Section B, 

Port Configuration

Section C, 

Clocking Configuration

Section D, 

Trunk Configuration

Section E, 

Channel Configuration

Section F, 

SP201-SA Warmstart

Copyright 2003 Encore Networks, Inc.

All rights reserved.

Содержание SignalPath 201-SA

Страница 1: ...trunk circuit from one external device through the SP201 SA to another external device comprises trunk connections to two ports The SignalPath configuration software defines each side of the trunk ci...

Страница 2: ...cable in one of the following ways Connect an E1 cable to the RJ48C port labeled Port 1 or Connect an E1 cable to the BNC Rx and Tx ports labeled Port 1 b For the ISDN trunk do one of the following Fo...

Страница 3: ...pply to a power source a power outlet and switch the power on Note Shipments within North America include a power cable for connection to the power outlet For shipments outside North America contact y...

Страница 4: ...list above 1 20 current 11 Ports 1 and 2 Ports 3 and 4 Select the configuration that supports your SP201 SA s port connections and press the Enter key The List of Valid LIMs shown is for a four port S...

Страница 5: ...ou are configuring user config clocks Clocking synchronization for the SP201 SA Enter the trunk number 1 4 from which this card is to derive its clock source Or enter 0 if this card is to use its inte...

Страница 6: ...E1 120 Ohm 1 G704 CRC 2 G704 noCRC 3 G704 MF CRC 4 G704 MF noCRC enter E1 frame type currently G704 MF no CRC For E1 lines 3 or your E1 frame type Frame type for trunk For T1 lines line coding type ch...

Страница 7: ...ISDN signaling Section E 6 Channel Configuration for NI2 ISDN What the terminal displays What you type What you are configuring user config dt all All DTMF channels Set 1 1 thru 2 31 out of service y...

Страница 8: ...The following four questions appear only if you answered y to the previous question Use 911 Operator Services Signaling y or n current n n No use of 911 support Max nbr of ANI digits to send R1 0 all...

Страница 9: ...Uruguay 12 Greece 25 Venezuela 13 Indonesia Outgoing R2 converter mode 1 25 current CCITT 1 or your country code The country code for the version of R2 signaling this SP201 SA will use Request R2 call...

Страница 10: ...sent to N5 current Enter up to 18 digits Press Enter to leave this field empty Digit string that causes the C11 operator code to be sent to N5 Digits that cause C12 to be sent to N5 current Enter up...

Страница 11: ...N5 y or n current n n No support of caller ID ANI Note Although N5 does not use ANI some networks require ANI in all calls Answering y here places a fixed ANI in each call originating from N5 Generate...

Страница 12: ...Type 3 D 16 E1 Inactive Network ETSI ISDN 4 D 16 E1 Inactive Network ETSI ISDN ISDN Trunk Number Enter value 3 4 or exit p where p is the port number 3 or 4 ISDN trunk p Select interface type user 0...

Страница 13: ...Type 3 D 24 T1 Inactive Network NI2 ISDN 4 D 24 T1 Inactive Network NI2 ISDN ISDN Trunk Number Enter value 3 4 or exit p where p is the port number 3 or 4 ISDN trunk p Select interface type user 0 or...

Страница 14: ...nce Guide What the terminal displays What you type What you are configuring user warmstart Implementation of the ISDN configuration This action will drop any calls that are in progress Do you really w...

Отзывы: