1. Keep tray closed to protect eyewash heads and shut off flow. Do not lean on tray when in open position.
2. Clean the vessel with mild soap and water as needed. Rinse well and refill with potable water to appropriate fill-line and
add Hydrosep
®
water preservative.
3. Unit should be drained, flushed, and refilled with clean potable water and Hydrosep
®
water preservative. Encon
recommends cleaning and replacing the fluid every 90 to 120 days (not to exceed 180 days). Follow the directions
printed on the Hydrosep
®
bottle.
4. Unit should be activated for 15 seconds to flush lines and inspected annually to verify proper operation. Refill to
appropriate fill-line after each test and add Hydrosep
®
water preservative if six gallons (cumulative) or more is used
during the testing procedures. Inspection should include examination of hose connecting reservoir and basin, and
reservoir should be free of fungi, algae or other foreign materials.
5. Test records should be maintained verifying compliance with testing procedures.
COMPONENT LIST FOR TRANSPORT CART
1.
Base Plate (1)
11. Bolt, ¼”-20 x 2½”lg (4)
2.
Front Leg (2)
12. Bolt, ¼"-20 x 2¾"lg (2)
3.
Upper Support (1)
13. Bolt, ¼”-20 x 1½”lg (6)
4.
Rear Leg (2)
14. Bolt, ¼"-20 x 1¾"lg (4)
5.
Upper Frame (1)
15. Bolt, ¼”-20 x ¾”lg (16)
6.
Lower Support (1)
16. Lock Nut ¼”-20 (28)
7.
Axle (1)
17. Flat Washer ⅝” (4)
8.
Locking Caster (2)
18. Cotter Pin (2)
9.
10” Wheel (2)
19. Stop Plate (1)
10. Axle Support (2)
20. Hand Grip (2)
TOOLS REQUIRED
1. Hammer
2. Pliers
3. 7/16” Wrench (2)
INSTALLATION INSTRUCTIONS FOR TRANSPORT CART
1. Attach stop plate to base plate with two ¼”-20 x ¾” bolts and lock nuts.
2. Insert post on locking caster in base plate sockets, until caster locks. Note orientation on base plate. Ensure that the gap
on the tension ring of the locking castor post does not align with the weld seam in the socket. Repeat step on other side.
3. Attach axle support to base plate, using two ¼”-20 x ¾” bolts and lock nuts. Repeat step on other side.
4. Insert axle through two axle supports
5. Place 10” wheel on axle with flat washer on each side on wheel. Repeat step on other side.
6. Install cotter pin through hole on axle to secure 10” wheel. Repeat step on other side.
7. Install front leg to base assembly using two ¼”-20 x ¾” bolts and lock nuts.
8. Install rear leg to base assembly using two ¼”-20 x ¾” bolts and lock nuts. Do not attach front leg to rear leg.
9. Repeat steps 7 and 8 for other side of unit.
10. Insert upper frame into mating hole on front leg. Secure upper frame to front legs using four ¼”-20 x 2½” bolts and lock
nuts.
11. Slip hand grip onto rear leg, two places.
12. Attach upper support to upper frame using four ¼”-20 x 1½” bolts and lock nuts.
13. Attach long surface of lower support to upper frame using two ¼”-20 x 1½” bolts and lock nuts as shown. Note
orientation and location of lower support.
14. Attach J-Hook to hole in upper support using two ¼”-20 x ¾” bolts and lock nuts as shown. J-hook supplied with Gravity
Fed eyewash.
15. Place Gravity Fed Eyewash and receptacle on cart as shown in
Figure 4
below.
16. Test for proper operation.
17. Place station in desired location. Lock front wheels by depressing silver tab on wheels.