Users’ Manual 

EDS-71V/P Single point borehole extensometer 

  

  

 

Page

 | 

12

 

 
 
 
CAUTION: 

Never rotate shaft of displacement sensor in respect to the outside body. This will permanently 
damage the sensor. During checking pull / push shaft only axially. A pin has been provided at 
end of displacement sensor that sits flush in a groove in sensor body. 

3.3  Procedure 

3.3.1  Refer to figure 2-1 and 2.2. Remove cover (19) and take out polythene bag that contains requisite 

quantity of reference buttons (15), link plates (16), sensor tightening nut (17), locknuts (18), M6 x 
100 or 125 mm or 150 mm cheese head screw (24) depending upon type of housing and locking 
nuts (25). 

3.3.2  Remove guide plate (6) with 2 mm Allen key and hollow bolts (12) from holes marked 1, G and V   

from flanged housing (5) and place latter flat on clean ground around 1 m away from borehole.  

CAUTION:

  Always mark a line between flanged housing (5) and adopter cum guide plate (6) before  

dismantling so that it can be aligned properly while assembling the sensor (20).   

3.3.3  Cut grout and air vent tubes ( 

Φ

12 mm outside dia.x 1 mm thick supplied in coil form) to required 

length. Generally, lower end of grout tube is kept at a level higher than anchor. Grout should cover 
anchor to mouth or be around 1 m from face of borehole whichever distance is less. To determine 
length of grout tube, ensure that around 1.5 m is required outside the reference plate (14) for ease 
in attaching it to grout pump. Air vent tube should be projected around 0.3 m is outside reference 
plate (14). Lower end of air vent tube should always be at a higher level than lower end of grout 
tube. While inserting anchor in borehole, lowest end of grout tube is tied with a cable tie to the 
connecting rod 

NOTE: 

In upward to horizontally sloping borehole, grout tube should be about 2 m longer than 
specified depth of anchor and taped around 100 mm below far end of anchor. Tape grout tube 
every 2 m with a PVC tape to plastic tube of connecting rod assembly to prevent it from 
swinging loose.   

NOTE: 

In upward to horizontally sloping borehole, air vent tube should be about 1.5 m longer than 
specified depth of anchor and taped around 100 mm above far end of anchor. Tape air vent 
tube every 2 m with a PVC tape to the nylon tube of connecting rod assembly to prevent it 
from swinging loose. Top end of air vent tube should be at a level higher than anchor.  

CAUTION: 

In upward to horizontally sloping borehole, care should be taken that air vent tube is taped 
around 100 mm beyond rear end of anchor and should not get detached. This is very 
necessary for the grout to fill in up to end of anchor.

 

3.3.4  Guide grout tube through hollow bolt (12), washer (11) and rubber bush (10) of hole marked G at 

bottom of flanged housing and corresponding holes on guide plate (6) and reference plate (14), 
the grout tube is around 1.5 m outside the reference plate. Similarly, guide the air vent tube through 
hollow bolt of hole marked V at bottom of flanged housing; the vent tube is around 0.3 m outside 
the reference plate (14). 

3.3.5  Tighten corresponding hollow bolt (12) with spanner size 21 mm and long hollow bolt (7) to firmly 

grip nylon grout and air vent tubes but not to squeeze them. 

CAUTION:

   Always tight hollow bolts (12) 2 nos. firstly and then long hollow bolt (7) at the end. 

CAUTION: 

In upward to horizontally sloping borehole, be particularly careful in tightening the hollow bolts 
(12) properly as grout may leak through into the reference head assembly during the grouting 

Содержание EDS-71P

Страница 1: ...ucknow UP 226011 India P 91 522 2661039 42 Email geotech encardio com www encardio com International UAE Qatar Bahrain Bhutan Europe USA India Lucknow Delhi Kolkata Mumbai Chennai Bangalore Hyderabad...

Страница 2: ...REHOLE EXTENSOMETER BHE 4 2 1 General Description 4 2 1 1 Reference head assembly 4 2 1 2 Displacement sensor 4 2 1 3 Connecting rod assembly 6 2 1 4 Anchor 7 2 2 Accessories 8 2 2 1 Junction box 8 2...

Страница 3: ...ential roof or wall falls before they actually occur Roof or wall falls in underground cavities are almost invariably preceded by measurable sags as the strata opens up and the movement usually occurs...

Страница 4: ...his manual WARNING Warning messages calls attention to a procedure or practice that if not properly followed could possibly cause personal injury CAUTION Caution messages calls attention to a procedur...

Страница 5: ...he end to get a thorough grasp of the subject You will find a lot of unexpected information in the sections you feel you may skip For description of vibrating wire borehole extensometers manufactured...

Страница 6: ...BHE reference head assembly Reference head assembly is supplied packed from factory as per items listed in figure 2 1 The sensor is separately supplied but it is very convenient to assemble it at sit...

Страница 7: ...r Junction box assembly Reference button Reference plate Sensor lock nut Sensor tightening nut Link plate Center pillar 17 19 18 21 23 20 Cover 16 15 14 13 22 Nipple with chuck nut Grub screw M4x5 8 b...

Страница 8: ...d to downward holes This is because in vertically upward holes the connecting rod is in tension whereas in downward holes it is in compression resulting in sagging or buckling Longer the extensometer...

Страница 9: ...in flanged housing its face extends around 20 mm beyond rubber bush 10 Proper sealing in reference head assembly is especially necessary for upwards to horizontally slanting holes for preventing any...

Страница 10: ...nsor to the observation room Alternatively a junction box is available for termination of cable from sensor and transmitting the signal through a multi core cable to the observation room 2 2 2 Cable F...

Страница 11: ...oth strips soaked in cement during installation 3 1 3 Insert reference head assembly centralised in the 63 mm borehole Taking holes on flange as reference drill four holes 12 mm diameter x 125 mm deep...

Страница 12: ...21 4 6821 4 6823 40 05 39 99 50 00 7947 7 7947 7 7946 0 7947 50 00 50 01 Error fs 0 23 0 03 Digit f X 10E 3 Linear gage factor G 8 848E 03 mm digit Thermal factor K 0 003 mm C Polynomial constants A 1...

Страница 13: ...9150 1 9150 48 00 0 00 Max error FS 0 16 Linear gage factor G 25 83 mm Volts Displacement D is calculated with the following equation Linear D mm G R1 R0 R1 current reading R0 is initial reading in V...

Страница 14: ...le lowest end of grout tube is tied with a cable tie to the connecting rod NOTE In upward to horizontally sloping borehole grout tube should be about 2 m longer than specified depth of anchor and tape...

Страница 15: ...ss rod is supplied in coil form using cable ties It is very stiff material and must be carefully handled when unwinding as the end may snap back and cause personal injury 3 3 8 Guide end of fibreglass...

Страница 16: ...nsion can be monitored In other words if only compression is expected set zero reading of sensor by extending shaft by around 10 mm If only extension is expected set zero reading of sensor by extendin...

Страница 17: ...out pipe to grouting machine or pump grout till the entire cavity is filled and grout flows out of air vent pipe Be very careful that grout flowing out of air vent tube does not get into the flanged h...

Страница 18: ...sensor to connecting rod clearly noting position of extensometer 1 CAUTION Never rotate shaft of displacement sensor in respect to the outside body This will permanently damage the sensor During inst...

Страница 19: ...nstallation of the multi position borehole extensometer 3 4 1 Soldering iron 25 watt 3 4 2 Rosin 63 37 solder wire 3 4 3 Thread sealant Loctite 290 or equivalent 3 4 4 Cable jointing compound 3 4 5 Ac...

Отзывы: