background image

Содержание TENS-6000

Страница 1: ...TENS 6000 INSTRUCTION MANUAL El TENS 6000 Please read the instruction manual before u Caution Federal law USA restricts this device to sell by or on the order of a phy ...

Страница 2: ...I 4 3 Connect lead wires to unit 12 4 4 Place electrodes on skin 13 4 5 Adjust Output 13 4 6 Select the mode 14 Chapter Page 4 7 Adjust the Pulse Rate 14 4 8 Adjust the Pulse Width 15 4 9 Adjust Timer 15 4 10 Adjust Channel Amplitude 15 4 II Turn Unit Off 17 4 12 Patient Compliance Timer 17 4 1 3 Portability 20 4 14 Low Battery indicator 20 4 15 Battery 21 4 16 Care of Electrodes 21 4 17 Care of E...

Страница 3: ...ed over or in proximity to cancerous lesions 1 3 7 For external use only 1 3 8 Do not use TENS on the eye area 1 3 9 This device should be used only under the continued supervision of a physician 1 3 10 Safety of TENS devices for use during pregnancy or delivery has not been established 1 3 11 Electronic equipment such as ECG monitors and ECG alarms may not operate properly when TENS is in use 1 3...

Страница 4: ...ulation levels are uncomfortable or become uncomfortable reduce the stimulation amplitude to a comfortable level and contact your physician if problems persist 1 5 Adverse Reactions 1 5 1 Possible skin irritation or electrode burn under the electrodes may occur 1 5 2 Possible allergic skin reaction to tape or gel may occur 3 2 PRODUCT DESCR PT ONS Z I none ana ncnr pnnci 0p View Knob Cover Channl ...

Страница 5: ...nuous mode DECREASE decrease control button using a inverted triangle button This button will carry the decrease character to decrease the pulse width from 300 50us and to decrease the pulse rate from ISO to 2Hz and to decrease the timer from continuous mode to 90 to 5 min MODE button using a round button on the right side of the control panel This button will carry the character to select for a S...

Страница 6: ...0 to 300us are fully adjustable The normal mode is quite versatile because it may be applied with a variety of rate and width settings 3 3 MRW Modulated Rate and Width Mode The pulse rate and width are automatically varied in a cycle to produce a pleasant massage like sensation It s believed that nerves can become accustomed to or accommodated to the same electrical stimulus after a period of time...

Страница 7: ...f Channel 2 is fixed at 100 Hz Stimulation is burst on for 1 0 second then off for 1 0 second There illustration each pulse as a vertical line Pulse width from 50 300us is fully adjustable NOTE Always read this instruction manual before use 1sec sec 1sec 4 INSTRUCTIONS FOR USE PREPARATION FOR USE 4 1 Check Battery Proceed to insert a fresh 9V alkaline or rechargeable battery into the battery compa...

Страница 8: ...o this step be sure the unit is completely turned OFF Holding the insulated portion of the lead wire connector insert the angled L plug into the receptacle on the top of the main unit Please ensure the leads are inserted correctly The unit hastwo output receptacles which are controlled by Channel I and Channel 2 Amplitude Control knobs at the top of the unit You may choose to use one channel with ...

Страница 9: ...or Channel I or 2 clockwise Then you will hear a Bl sound Before you increase the Amplitude you must select the mode rate andwidth jp 4 6 Select the mode Press MODE button to set the stimulation mode recommended by your physician or therapist For details about stimulating waveform and sequences please refer to Sec 3 Stimulation Modes descriptions Caution Please consult physicians for your suitable...

Страница 10: ...D screen as long as the unit is in operation Slowly turn the Channel Amplitude control until you reach the setting recommended by your medical professional Repeat for the other channel if both channels are to be used Caution If the stimulation levels ore uncomfortable or become uncomfortable reduce the stimulation intensity to a comfortable level and contact your physic on if problems persist Oper...

Страница 11: ...er First press and hold Mode button and turn on the either one amplitude knob simultaneously to initiate patient compliance timer Individual treatment time Press INCREASE button triangle button or DECREASE button inverted triangle button to seenext record of treatment time with the number of times or previous record of treatment time with the number of times Press and hold Set button for 3 seconds...

Страница 12: ...all the records including individual treatment time record and cumulative treatment time record The patient compliance timer will keep the records even when the battery has no charge Only when users press and hold Set or Mode Set the records will be deleted H2 ICU CARE AND MAINTENANCE 4 13 Portability Your Unit is portable and may be clipped to a belt shirt pocket bra or other clothing 4 14 LowBat...

Страница 13: ...ith talcum powder will reduce tangles and prolong the life in Keep this device into the handy carrying case and storage at room temperature 6 SPECIFICATION Channel Power Source Output waveform Pulse Width Pulse Frequency Adjustable Intensity Levels Five Massage Modes Patient Compliance Timer Operation ambient Storage transportation Timer Lead wires Safety standard Dual isolated between channels 9V...

Страница 14: ...tly refer to the chart below to determine what may be wrong Should none of these measures correct the problem the unit should be serviced Self Adhesive Electrodes 9 V Battery Lead Wires Instructional Manual The LCD indicator lights up but unit does not function properly 1 Check all control settings Are they set to values prescribed by your medical professional 2 Are electrodes in proper position 3...

Страница 15: ......

Отзывы: