Empire OLI-24-1 Скачать руководство пользователя страница 12

28095-6-0115

Page 12

MAIN

PILOT

Learn

MOTOR

COMM.

POWER

IPI

Continuous

Pilo

t

Off/O

n

Remote/Off

S

I

ADJ.

(GND)

HI/LO

Solenoid

ORANGE

(IGNITOR)

BLACK

(SENSOR)

BLACK

ORANGE

GREEN

WHITE

BROWN

PILOT

GAS CONTROL

VALVE

ELECTRONIC

CONTROL MODULE

AF-4000 B/P

RED

BLACK

BLACK

BROWN

RED

ORANGE

N/A

CUSTOMER PROVIDED

WALL SWITCH

Main Burner Flame Pattern

The main burner flame will be completely yellow. 

Main Burner Flame Ignition and extinction

When the main burner is ignited it will take a few seconds for the 

full flame pattern to develop.
When the main burner is extinguished it will take a few seconds for 

the flames to disappear. 

MaIn Burner FlaMe cHaracterIstIcs

Keep the control compartment and burner area surrounding the 

burner clean.
Always keep the appliance area clear and free from combustible 

materials, gasoline, and other flammable vapors and liquids.
Never obstruct the flow of combustion and ventilation air. Keep the 

front of the appliance clear of all obstacles and materials.

cleaning Instructions

This appliance is built using mostly high-grade stainless steel to 

resist rust-through. In outdoor applications, all stainless steel will 

develop a dull patina and, depending on the local environment 

and on the materials used in the installation, may develop some 

surface oxidation (rust). This does not affect the performance of 

the  fireplace,  and  does  not  require  any  action  to  correct.  If  you 

prefer keeping your fireplace front looking factory-fresh, clean it as 

required with stainless steel cleaner.

When installation application includes highly acidic applications 

such as mortar or stone etching, do not remove the protective PVC 

film from the stainless steel until after this application is complete. 

Once the film has been removed we recommend that the appli

-

ance be cleaned with a stainless steel cleaner immediately.

Please note that areas where the film has been formed (corners, 

hems,  etc.)  may  require  extra  cleaning  due  to  the  properties  of 

the film. Ensure that all protective film has been removed from the 

fireplace prior to burning the appliance.  

cleanInG and serVIcInG

wIrInG

note:

 The fireplace may be operated without the remote by 

connecting the brown control module wires to a wall switch. The 

remote/off switch on the control module must be in the "OFF" 

position.

Содержание OLI-24-1

Страница 1: ...red in the vicinity of this or any other ap pliance DANGER CARBON MONOXIDE HAZARD This appliance can produce carbon monoxide which has no odor Using it in an enclosed space can kill you Never use this...

Страница 2: ...Before Fully Installing the Appliance 8 Gas Supply 9 Operation Instructions Flame Appearance 10 OLI 24 30 Lighting Instructions 11 Main Burner Flame Characteristics 12 Cleaning and Servicing 12 Wiring...

Страница 3: ...avoided could result in death or serious injury CAUTION Indicates a hazardous situation which if not avoided could result in minor or moderate injury NOTICE Addresses practices not related to personal...

Страница 4: ...erform service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or adsorption on wall...

Страница 5: ...h apply to the installation of a vented decorative gas log set in a solid fuel burning fireplace This appliance is only for use with the type of gas indicated on the rating plate Instructions to Insta...

Страница 6: ...NAT For appliances for fixed fuel piping system and equipped with an appliance gas pressure regulator the required mani fold pressure in inches water column 10 for LP and 3 5 NAT For appliances for f...

Страница 7: ...m kg of stored fuel capacity and not less than a total free area of 10 square inches 64 5 sq cm If ventila tion openings at floor level are in a side alll there shall be at least two openings The bott...

Страница 8: ...lid Fuel Burning Fireplaces Model A B C D OLI 24 27 18 34 18 OLI 30 30 18 36 18 The dimensions shown and defined in the fireplace instructions are minimum clearances to maintain in installing this hea...

Страница 9: ...ble by the authority havingjurisdiction ThestateofMassachusettsrequiresthataflexible appliance connector cannot exceed three feet in length Figure 2 Pressure Testing of the Gas Supply System 1 To chec...

Страница 10: ...grate Inspect and clean burner air intake hole Remove lint or particles with brush Failure to keep air intake hole clean will result in sooting and poor combustion ANNUAL CLEANING INSPECTION Refer to...

Страница 11: ...ect the appliance and to replace any part of the control system and any gas control which has been under water LIGHTING INSTRUCTIONS TO TURN OFF GAS TO APPLIANCE 1 Locate On Off gas cock and turn cloc...

Страница 12: ...high grade stainless steel to resist rust through In outdoor applications all stainless steel will develop a dull patina and depending on the local environment and on the materials used in the instal...

Страница 13: ...l use if batteries are replaced or if a replacement transmitter is purchased from your dealer or the factory In order for the module to accept the transmitter security code be sure the slide button on...

Страница 14: ...e Holder 4 P245 P265 Orifice LP 4 P301 P209 Orifice NAT 5 R10808 R10808 Air Shutter 6 28739 28740 Burner with Bracket 7 R10814 R10814 Spark Probe 8 28089 28089 Valve Shield 9 R10810 R10810 Gas Valve L...

Страница 15: ...anty parts All parts listed in the Parts List have a Part Number When ordering parts first obtain the Model Number and Serial Number from the name plate on your equipment Then determine the Part Numbe...

Страница 16: ...e must be installed by a qualified installer and operated in accordance with the instructions furnished with the appliance A bill of sale cancelled check or payment record should be kept to verify pur...

Отзывы: