Empire FRBTP-1 Скачать руководство пользователя страница 1

22775-3-1009

Page 1

EMPIRE

EMPIRE

Comfort Systems

FRBTP-1

INTRODUCTION

This remote control system was developed to provide a safe, reliable, and user-friendly remote control system for gas 

heating appliance. The system can be operated thermostatically or manually from the transmitter. The system operates on 

radio frequencies (RF) within a 20 feet range using non-directional signals. The system operates one of 1,048,576 secu-

rity codes that are programmed into the transmitter at the factory; the remote receiver’s code must be matched to that of 
the transmitter prior to initial use.

IF YOU CANNOT READ OR UNDERSTAND THESE INSTALLATION INSTRUCTIONS DO NOT 

ATTEMPT TO INSTALL OR OPERATE

Review 

COMMUNICATION SAFETY SECTION

 under 

TRANSMITTER

 section and 

THERMO SAFETY SECTION

 under 

REMOTE 

RECEIVER

 section. These signal/temperature safety features shut down the fireplace system when a potentially unsafe condition 

exists.

INSTALLATION AND OPERATING INSTRUCTIONS

The transmitter operates on 2AAA-size 1.5V batteries. It is recommended that ALKALINE bat-

teries always be used for longer battery life and maximum operational performance.

IMPORTANT:

 New or fully charged batteries are essential for proper operation of the multi-

function transmitter.

Insert 2 AAA-size 1.5 V batteries into the battery transmitter, positioning the (+) and (-) ends 

of the batteries as indicated on the casing. When the batteries are inserted, the screen below 

(with similar numbers) will display.

Note:

 If a LOW battery icon appears on the screen, check the position of the batteries.

Note: 

Due to the sensitive temperature-monitoring 

components in the transmitter, it may be necessary to 

allow the transmitter to stabilize to room temperature 

before accurate room temperatures are displayed 

on the screen. If the transmitter is activated from a 

severe cold condition, it can take up to fifteen minutes 

for accurate temperature readings to appear.

1.  PROGRAM  FOR:  Flashes  when  programming 

days of week and periods of the day. When in normal state, only current DAY displays. 

When programming or in PROGRAM mode, both day and week will appear.

2.  DAY –Flashes when current day or day of week is being programmed.

3.  PERIOD – Flashes when current period of day or period of week is being programmed.

4.  MODE – Indicates operation MODE of system.

• 

ON indicates the system is on, either manually, thermostatically, or program.

• 

Off indicates the entire system is turned off.

• 

THERMO indicates the system will automatically cycle ON/OFF, depending on pro

-

grammed SET temperature.

 

• PROGRAM – indicates the system is operating with PROGRAMMED settings.

5.  START AT – Flashes when programming the time to turn system ON.

6.  SET – Indicates desired SET room temperature, when in THERMO or PROGRAM mode.

7. 

°

F / 

°

C – Factory programmed in 

°

F. ( 

°

C indicates degrees in Celsius) 

8.  TIME/TEMP – Displays the CURRENT room temperature. In same frame, the current time 

will  display  in AM  or  PM.  You  must  depress  the  TIME/TIMER  button  to  display  current 

time.

9.  LOW – Battery power is low. Replace batteries within 2 weeks.

10.  TIMER – When displayed, indicates countdown timer in operation.

11.  OVERRIDE – Displays when “programmed” SET temperature is overridden.

12.  FLAME – Single flame symbol indicates burner/valve is operational.

Содержание FRBTP-1

Страница 1: ...screen check the position of the batteries Note Due to the sensitive temperature monitoring components in the transmitter it may be necessary to allow the transmitter to stabilize to room temperature...

Страница 2: ...tton on the front of the transmitter NOTE You will need to press the SET button confirming F if you want the temperature readings to be in F INITIAL SET UP PROGRAMMING OF TRANSMITTER Follow the proced...

Страница 3: ...urrent HOUR press the SET button on the front of the transmitter and the MINUTE digits will begin flashing on the LCD screen 4 To set the current MINUTES press the UP or DOWN button setting to the cor...

Страница 4: ...TURE press the UP or DOWN button 7 When the desired SET TEMPERATURE displays then press the PROG button 8 After pressing the PROG button in step 7 the next PERIOD of the same or next day will display...

Страница 5: ...variation is called the SWING or TEMPERATURE DIFFERENTIAL The normal operating cycle of a fireplace system may be 2 4 times per hour depending on how well the room or home is insulated from the cold...

Страница 6: ...e the SET temperature during any period adjusting the SET temperature to a CONSTANT new SET HOLD temperature 1 Press the UP or DOWN button to change the SET temperature to the level desired The word O...

Страница 7: ...me options Available countdown times are 15 min 30 min 45 min 1 hr 1 hr 30 min 2 hr 2 hr 30 min and each additional half hour up to nine hours 3 To set the TIMER press the SET button on the transmitte...

Страница 8: ...transmitter be taken out of the normal operating range or should the transmit ter s batteries fail or be removed REMOTE RECEIVER The remote receiver operates on 4 AA size 1 5V batteries IT is recomme...

Страница 9: ...nic module directly to 110 120VAC power Consult gas appliance manufac turer s instructions and wiring schematics for proper placement of all wires All electronic modules are to be wired to manufacture...

Страница 10: ...ications WIRING INSTRUCTIONS A qualified electrician or a gas technician who is familiar with the gas appliance and gas valves that will be operated by this remote should install the remote control sy...

Страница 11: ...nsmitter to change the system to THERMO Advance the SET temperature on the transmitter to a temperature of at least 2 F 1 C above the ROOM temperature displayed on the LCD screen With this manual sett...

Страница 12: ...nstalled properly If one battery is installed backward receiver will not operate in remote mode Be sure battery output is 2 5 volts or more Slide switch is independent of battery condition 2 Be sure t...

Страница 13: ...9A 3003 receiver 2439A 33 1RX FCC REQUIREMENTS NOTE THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFERENCE CAUSED BY UNAUTHORIZED MODIFICATIONS TO THIS EQUIPMENT SUCH MODIFICATIONS COULD...

Страница 14: ...and the area the appliance is posi tioned in When using a Remote Control Thermostat both burner switches need to be in the on position When the red button is pressed with both burner switches on the...

Страница 15: ...will automatically cycle ON OFF depending on programmed SET temperature 4 PROGRAM indicates the system is operating with PROGRAMME settings OTHER OPERATIONS Press corresponding buttons on TRANSMITTER...

Страница 16: ...n to flash 6 Program SET TEMP by pressing UP or DOWN button 7 Again press PROG button The next PERIOD and DAY will begin to flash 8 Repeat steps 2 through 7 for all 7 DAYS until each PERIOD OF DAY is...