12821-8-0907

Page 3

•  Due  to  high  temperatures,  the  room  heater  should  be 

located out of traffic and away from furniture and drap-

eries. 

•  Children and adults should be alerted to the hazards of 

high surface temperature and should stay away to avoid 

burns or clothing ignition.

•  Young children should be carefully supervised when they 

are in the same room as the room heater.

•  Clothing or other flammable material should not be placed 

on or near the room heater.

•  Due to high surface temperatures, keep children, clothing 

and furniture away.  

•  Keep burner and control compartment clean.
•  Installation and repair should be done by a QUALIFIED 

SERVICE PERSON.  The room heater should be inspected 

before use and at least annually by a qualified service 

person.  More frequent cleaning may be required due to 

excessive lint from carpeting, bedding material, etc.  It 

is  imperative  that  control  compartments,  burners  and 

circulating air passageways of the room heater be kept 

clean.

•  DO NOT put anything around the heater that will ob-

struct the flow of combustion and ventilation air.  See 

clearances.

•  DO keep the appliance area clear and free from combus-

tible material, gasoline and other flammable vapors and 

liquids.

•  DO  examine  venting  system  periodically.    Clean  and 

replace damaged parts.  Examinations should be made 

at the start of the heating season and also in mid heating 

season under average conditions.

•  DO  examine  burners  periodically.    Clean  and  replace 

damaged parts.

•  DO NOT use this heater if any part has been under water.  

Immediately call a qualified service technician to inspect 

the heater and to replace any part of  the control system 

and any  gas control which has been under water.

THIS IS A HEATING APPLIANCE

DO NOT OPERATE THIS APPLIANCE WITHOUT FRONT PANEL INSTALLED.

Attention: 

During operation of vented room heater the gasket for observation hole cover, observation hole cover and cover plate for 

observation hole cover must be attached to combustion chamber and secured with two (2) wing nuts.

IMPORTANT SAFETY INFORMATION

Содержание RH-25

Страница 1: ...mma ble vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your...

Страница 2: ...ng 7 Vent Safety Shutoff System 8 Reversible Vertical or Horizontal Diverter 8 Thermostat Operation 8 Lighting Instructions 9 Pilot Flame Characteristics 10 Main Burner Flame Characteristics 10 Mainte...

Страница 3: ...passageways of the room heater be kept clean DO NOT put anything around the heater that will ob struct the ow of combustion and ventilation air See clearances DO keep the appliance area clear and free...

Страница 4: ...form service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or adsorption on walls...

Страница 5: ...r Floor pad is available from Empire Comfort Systems Inc Part Number DVP 1 Quali ed Installing Agency Installation and replacement of gas piping gas utilization equip ment or accessories and repair an...

Страница 6: ...pped on the bottom in which condensation and foreign particles may collect Figure 2 Method of Installing a Tee Fitting Sediment Trap Pressure Testing of the Gas Supply System 1 To check the inlet pres...

Страница 7: ...n in which the facilities for ventilation permit satisfactory combustion of gas and proper venting under normal conditions In buildings of conventional frame brickorstoneconstructionwithouttightstormw...

Страница 8: ...the draft diverter 2 Inside your yellow instruction envelope will be a 1 1 2 x 2 1 4 38mm x 51mm vent safety switch hole cover plate and two 2 1 2 screws for attachment of vent safety switch hole cov...

Страница 9: ...oximately 60 seconds There will be an audible click when the safety magnet in the gas control is de energized Pilot can now be relit Repeat steps 5 through 10 12 Turn gas control knob counterclockwise...

Страница 10: ...will be a short blue inner ame with a larger lighter blue secondary ame The burner ame may have yellow tips when hot Dust in the combustion air will produce an orange or red ame Do not mistake the ora...

Страница 11: ...hen knob is released a Pilot ame not covering the thermocouple properly b Defective thermocouple c Defective magnet in the safety section of valve 4 Poor thermostat control a Thermostat needs calibrat...

Страница 12: ...Burner RH 35 6 24 R 1195 Thermocouple 36 25 R 1227 Pilot Burner with Ori ce Nat 25 R 1228 Pilot Burner with Ori ce LPG 26 11698 Pilot Tubing 27 R 6120 Electrode and Wire Assembly USE ONLY MANUFACTURER...

Страница 13: ...12821 8 0907 Page 13 PARTS VIEW...

Страница 14: ...g front Attention Wiring harness on blower is factory assembled and installed If wiring harness becomes disassembled use the follow ing steps to reassemble the wiring harness 1 Attach 1 pinterminalfro...

Страница 15: ...rature dial or thermostat to lowest setting 2 Turn knob on gas control to OFF depressing slightly Do not force Cleaning The blower wheel will collect lint and could require cleaning once a year If the...

Отзывы: